1,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.46 kW
6.96 kW
El input
1.65 kW
2.37 kW
COP
5.14
2.94
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
38 dB(A)
Sound power level outdoor
dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
129 %
Prated
7.68 kW
6.27 kW
SCOP
4.90
3.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.79 kW
5.55 kW
COP Tj = -7°C
3.03
2.04
Cdh Tj = -7 °C
0.998
0.998
Pdh Tj = +2°C
4.41 kW
3.60 kW
COP Tj = +2°C
4.84
3.24
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
3.03 kW
2.46 kW
COP Tj = +7°C
6.53
4.35
Cdh Tj = +7 °C
0.990
0.991
Pdh Tj = 12°C
1.71 kW
1.58 kW
COP Tj = 12°C
8.80
5.50
Cdh Tj = +12 °C
0.979
0.981
Pdh Tj = Tbiv
6.79 kW
5.55 kW
COP Tj = Tbiv
3.03
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.63 kW
6.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.33
2.12
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
5 W
5 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
0.05 kW
0.23 kW
Annual energy consumption Qhe
3237 kWh
3931 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.79 kW
9.17 kW
El input
2.01 kW
3.06 kW
COP
4.88
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
dB(A)
38 dB(A)
Sound power level outdoor
dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
131 %
Prated
8.36 kW
7.12 kW
SCOP
4.84
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.40 kW
6.38 kW
COP Tj = -7°C
2.90
2.04
Cdh Tj = -7 °C
0.998
0.998
Pdh Tj = +2°C
4.49 kW
3.79 kW
COP Tj = +2°C
4.74
3.29
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
3.07 kW
2.67 kW
COP Tj = +7°C
6.72
4.40
Cdh Tj = +7 °C
0.990
0.991
Pdh Tj = 12°C
1.69 kW
1.71 kW
COP Tj = 12°C
8.65
5.86
Cdh Tj = +12 °C
0.979
0.981
Pdh Tj = Tbiv
7.40 kW
6.38 kW
COP Tj = Tbiv
2.90
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.36 kW
7.12 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.32
2.15
WTOL
65 °C
65 °C
Poff
15 W
15 W
PTO
5 W
5 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Gas
Gas
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3570 kWh
4447 kWh