Certificate holders

Subtype

Air Source Heat Pump- R290-006

Certificate Holder
PERFEXIM Sp. z o.o.
ul. Samotna 2
61-441 Poznań
Poland
Registration number
041-K103-01
Certification Body
BRE
Subtype title
Air Source Heat Pump- R290-006
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,550 kg

Certification Date
10.10.2024
Testing basis
HP KEYMARK certification scheme rules rev. no.14
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

PHA-50 (50-006-0816-001) BLN-006TC1
Configure model
Model name
PHA-50 (50-006-0816-001) BLN-006TC1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.07 kW

6.10 kW

El input

1.27 kW

1.95 kW

COP

4.77

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

146 %

Prated

6.08 kW

6.06 kW

SCOP

4.83

3.71

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.36 kW

COP Tj = -7°C

3.09

2.33

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.40 kW

3.33 kW

COP Tj = +2°C

4.68

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.24 kW

2.17 kW

COP Tj = +7°C

6.20

4.70

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.36 kW

2.28 kW

COP Tj = 12°C

9.30

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.37 kW

5.36 kW

COP Tj = Tbiv

3.09

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.03 kW

5.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

30 W

30 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.44 kW

Annual energy consumption Qhe

2599 kWh

3372 kWh

PHA-50I (50-006-0816-101) BLN-006TC1
Configure model
Model name
PHA-50I (50-006-0816-101) BLN-006TC1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.07 kW

6.10 kW

El input

1.27 kW

1.95 kW

COP

4.77

3.12

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

146 %

Prated

6.08 kW

6.06 kW

SCOP

4.83

3.71

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.36 kW

COP Tj = -7°C

3.09

2.33

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.40 kW

3.33 kW

COP Tj = +2°C

4.68

3.66

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.24 kW

2.17 kW

COP Tj = +7°C

6.20

4.70

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.36 kW

2.28 kW

COP Tj = 12°C

9.30

7.01

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.37 kW

5.36 kW

COP Tj = Tbiv

3.09

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.03 kW

5.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

10 W

10 W

PTO

30 W

30 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.05 kW

0.44 kW

Annual energy consumption Qhe

2599 kWh

3372 kWh