0,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.42 kW
5.12 kW
El input
0.92 kW
1.92 kW
COP
4.80
2.66
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
128 %
Prated
4.30 kW
3.89 kW
SCOP
4.57
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.80 kW
3.44 kW
COP Tj = -7°C
2.96
2.09
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.32 kW
2.24 kW
COP Tj = +2°C
4.61
3.30
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.04 kW
1.84 kW
COP Tj = +7°C
6.01
4.27
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.35 kW
2.17 kW
COP Tj = 12°C
8.04
6.14
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.80 kW
3.44 kW
COP Tj = Tbiv
2.96
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.39 kW
3.03 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
12 W
12 W
PTO
25 W
25 W
PSB
12 W
12 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.91 kW
0.86 kW
Annual energy consumption Qhe
1941 kWh
2446 kWh