Certificate holders

Subtype

DC Inverter Air to Water Heat Pump R32 series 12KW

Certificate Holder
Guangdong Warmhouse Technology Co., Ltd.
No. 1, Dejin Road, Xingtan Town, Shunde District
528306 Xingtan
China
Registration number
011-1W0736
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DC Inverter Air to Water Heat Pump R32 series 12KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,500 kg

Certification Date
13.11.2023
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 1

Models

HL12HB
Configure model
Model name
HL12HB
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.90 kW

11.63 kW

El input

2.72 kW

3.89 kW

COP

4.37

2.99

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

133 %

Prated

9.39 kW

9.06 kW

SCOP

4.52

3.41

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.30 kW

8.01 kW

COP Tj = -7°C

3.20

2.21

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

5.08 kW

5.14 kW

COP Tj = +2°C

4.37

3.35

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.58 kW

3.59 kW

COP Tj = +7°C

5.34

4.07

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

4.20 kW

4.66 kW

COP Tj = 12°C

7.85

6.46

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

8.30 kW

8.01 kW

COP Tj = Tbiv

3.20

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.00 kW

8.53 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.39 kW

0.53 kW

Annual energy consumption Qhe

4295 kWh

5486 kWh