Certificate holders

Subtype

Series B R290 Mono-block Heat Pump 15kW

Certificate Holder
ECO-Warm Sàrl
4, Route Industrielle
1806 ST-LÉGIER-LA CHIÉSAZ
Switzerland
Registration number
011-1W0880
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Series B R290 Mono-block Heat Pump 15kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,700 kg

Certification Date
16.08.2024
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 1

Models

EWB15R2901
Configure model
Model name
EWB15R2901
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.33 kW

5.00 kW

COP

4.50

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

143 %

Prated

15.00 kW

15.00 kW

SCOP

4.95

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.46 kW

13.37 kW

COP Tj = -7°C

3.21

2.55

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

8.23 kW

8.39 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

7.22 kW

7.22 kW

COP Tj = +7°C

6.51

5.02

Cdh Tj = +7 °C

0.989

0.992

Pdh Tj = 12°C

8.79 kW

7.92 kW

COP Tj = 12°C

8.85

6.32

Cdh Tj = +12 °C

0.988

0.990

Pdh Tj = Tbiv

13.46 kW

13.37 kW

COP Tj = Tbiv

3.21

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.58 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

12 W

12 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

5.60 kW

Annual energy consumption Qhe

6258 kWh

8479 kWh