Certificate holders

Subtype

Series B R290 Mono-block Heat Pump 11kW

Certificate Holder
ECO-Warm Sàrl
4, Route Industrielle
1806 ST-LÉGIER-LA CHIÉSAZ
Switzerland
Registration number
011-1W0879
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Series B R290 Mono-block Heat Pump 11kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,200 kg

Certification Date
16.08.2024
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 1

Models

EWB11R2901
Configure model
Model name
EWB11R2901
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

11.00 kW

11.00 kW

El input

2.44 kW

3.66 kW

COP

4.50

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

141 %

Prated

11.00 kW

11.00 kW

SCOP

4.87

3.60

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.08 kW

9.85 kW

COP Tj = -7°C

3.16

2.43

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

6.40 kW

6.27 kW

COP Tj = +2°C

4.72

3.39

Cdh Tj = +2 °C

0.987

0.991

Pdh Tj = +7°C

5.96 kW

5.76 kW

COP Tj = +7°C

6.37

4.90

Cdh Tj = +7 °C

0.982

0.986

Pdh Tj = 12°C

7.05 kW

6.28 kW

COP Tj = 12°C

8.72

6.21

Cdh Tj = +12 °C

0.979

0.983

Pdh Tj = Tbiv

10.08 kW

9.85 kW

COP Tj = Tbiv

3.16

2.43

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.40 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.996

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

17 W

17 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.60 kW

3.50 kW

Annual energy consumption Qhe

4666 kWh

6305 kWh