0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.65 kW
9.06 kW
El input
1.58 kW
2.90 kW
COP
4.85
3.12
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
143 %
Prated
8.85 kW
8.43 kW
SCOP
4.77
3.64
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.83 kW
7.45 kW
COP Tj = -7°C
3.04
2.32
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.77 kW
4.86 kW
COP Tj = +2°C
4.80
3.64
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.48 kW
4.27 kW
COP Tj = +7°C
6.43
4.88
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.07 kW
4.87 kW
COP Tj = 12°C
8.17
6.45
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.83 kW
7.45 kW
COP Tj = Tbiv
3.04
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.60 kW
7.17 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
23 W
23 W
PTO
46 W
46 W
PSB
23 W
23 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.25 kW
1.26 kW
Annual energy consumption Qhe
3833 kWh
4783 kWh