1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.01 kW
7.25 kW
El input
1.74 kW
2.35 kW
COP
4.61
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
62 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
142 %
Prated
7.74 kW
7.23 kW
SCOP
4.78
3.63
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.85 kW
6.39 kW
COP Tj = -7°C
2.99
2.28
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.39 kW
4.10 kW
COP Tj = +2°C
4.92
3.72
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.42 kW
4.15 kW
COP Tj = +7°C
6.42
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.09 kW
4.83 kW
COP Tj = 12°C
8.24
6.19
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.85 kW
6.39 kW
COP Tj = Tbiv
2.99
2.28
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.61 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
24 W
24 W
PTO
30 W
30 W
PSB
24 W
24 W
PCK
43 W
43 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.13 kW
1.13 kW
Annual energy consumption Qhe
3345 kWh
4116 kWh