2,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.44 kW
16.47 kW
El input
3.39 kW
5.19 kW
COP
4.86
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
69 dB(A)
73 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
131 %
Prated
13.74 kW
14.08 kW
SCOP
4.50
3.35
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.16 kW
12.46 kW
COP Tj = -7°C
3.11
2.36
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.57 kW
7.65 kW
COP Tj = +2°C
4.41
3.27
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.31 kW
8.02 kW
COP Tj = +7°C
6.04
4.44
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.48 kW
9.34 kW
COP Tj = 12°C
8.02
6.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.16 kW
12.46 kW
COP Tj = Tbiv
3.11
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.73 kW
12.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
36 W
36 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.02 kW
1.28 kW
Annual energy consumption Qhe
6312 kWh
8673 kWh