2,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.93 kW
12.00 kW
El input
2.60 kW
3.98 kW
COP
4.59
3.01
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
131 %
Prated
10.24 kW
10.34 kW
SCOP
4.47
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.06 kW
9.15 kW
COP Tj = -7°C
3.02
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.88 kW
5.58 kW
COP Tj = +2°C
4.61
3.47
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.84 kW
6.95 kW
COP Tj = +7°C
5.84
4.19
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.73 kW
7.48 kW
COP Tj = 12°C
7.59
5.92
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.06 kW
9.15 kW
COP Tj = Tbiv
3.02
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.89 kW
9.42 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
2.07
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
33 W
33 W
PSB
8 W
8 W
PCK
42 W
42 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.36 kW
0.92 kW
Annual energy consumption Qhe
4736 kWh
6389 kWh