1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.92 kW
8.17 kW
El input
1.69 kW
2.73 kW
COP
4.67
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
62 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
130 %
Prated
7.20 kW
7.47 kW
SCOP
4.46
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.37 kW
6.61 kW
COP Tj = -7°C
3.39
2.33
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.19 kW
4.04 kW
COP Tj = +2°C
4.46
3.34
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.39 kW
4.25 kW
COP Tj = +7°C
5.66
4.24
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.99 kW
4.88 kW
COP Tj = 12°C
7.59
5.76
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
6.37 kW
6.61 kW
COP Tj = Tbiv
3.39
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.84 kW
6.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
2.11
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
40 W
40 W
PSB
8 W
8 W
PCK
35 W
35 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.37 kW
1.19 kW
Annual energy consumption Qhe
3335 kWh
4642 kWh