0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.80 kW
12.67 kW
El input
2.96 kW
4.18 kW
COP
4.32
3.03
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
31 dB(A)
Sound power level outdoor
51 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
142 %
Prated
9.42 kW
8.60 kW
SCOP
4.73
3.62
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.33 kW
7.60 kW
COP Tj = -7°C
3.10
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.82 kW
COP Tj = +2°C
4.79
3.65
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.42 kW
4.19 kW
COP Tj = +7°C
6.21
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.17 kW
4.95 kW
COP Tj = 12°C
8.06
6.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.33 kW
7.60 kW
COP Tj = Tbiv
3.10
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.53 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
12 W
12 W
PTO
21 W
21 W
PSB
12 W
12 W
PCK
26 W
26 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.88 kW
1.41 kW
Annual energy consumption Qhe
4115 kWh
4911 kWh