Certificate holders

Subtype

DC Inverter Air to Water Heat Pump Unit-R32-12T

Certificate Holder
POLYTROPIC SAS
4 chemin des Eclapons
69390 Vouries
France
Registration number
041-K093-04
Certification Body
BRE
Subtype title
DC Inverter Air to Water Heat Pump Unit-R32-12T
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,550 kg

Certification Date
31.07.2024
Testing basis
HP KEYMARK certification scheme rules rev. no.14
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Outdoor unit: WHL-12T, Indoor unit: RLB-100
Configure model
Model name
Outdoor unit: WHL-12T, Indoor unit: RLB-100
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.58 kW

11.14 kW

El input

1.85 kW

4.14 kW

COP

5.19

2.69

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

35 dB(A)

Sound power level outdoor

57 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

127 %

Prated

11.60 kW

11.04 kW

SCOP

4.70

3.24

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.26 kW

9.76 kW

COP Tj = -7°C

3.38

1.89

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.30 kW

6.11 kW

COP Tj = +2°C

4.69

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.13 kW

5.93 kW

COP Tj = +7°C

6.29

4.76

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.97 kW

6.92 kW

COP Tj = 12°C

6.02

5.80

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.26 kW

9.76 kW

COP Tj = Tbiv

3.38

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.23 kW

9.13 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.02

1.70

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

13 W

13 W

PTO

39 W

39 W

PSB

13 W

13 W

PCK

41 W

41 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.37 kW

1.91 kW

Annual energy consumption Qhe

5096 kWh

7039 kWh