1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
11.50 kW
El input
2.72 kW
3.88 kW
COP
4.39
2.96
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
68 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
136 %
Prated
10.20 kW
9.20 kW
SCOP
4.52
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
9.02 kW
8.14 kW
COP Tj = -7°C
2.90
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.51 kW
5.11 kW
COP Tj = +2°C
4.31
3.33
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.77 kW
3.56 kW
COP Tj = +7°C
6.50
4.66
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.74 kW
4.22 kW
COP Tj = 12°C
7.43
6.95
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
9.02 kW
8.14 kW
COP Tj = Tbiv
2.90
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.76 kW
8.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
2.00
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
56 W
56 W
PSB
13 W
13 W
PCK
93 W
93 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.44 kW
1.02 kW
Annual energy consumption Qhe
4646 kWh
5457 kWh