Certificate holders

Subtype

Ultimate series R290 15kW

Certificate Holder
Guangdong Luckingstar New Energy CO., LTD.
No.255 Hexiang East Rd, C area, Heshan Industrial Zone, Heshan City
Guangdong
China
Registration number
011-1W0853
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Ultimate series R290 15kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,700 kg

Certification Date
06.08.2024
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 2

Models

LWH-F15HVLZPN9
Configure model
Model name
LWH-F15HVLZPN9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.33 kW

5.00 kW

COP

4.50

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

143 %

Prated

15.00 kW

15.00 kW

SCOP

4.95

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.46 kW

13.37 kW

COP Tj = -7°C

3.21

2.55

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

8.23 kW

8.39 kW

COP Tj = +2°C

4.76

3.39

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

7.22 kW

7.22 kW

COP Tj = +7°C

6.51

5.02

Cdh Tj = +7 °C

0.989

0.992

Pdh Tj = 12°C

8.79 kW

7.92 kW

COP Tj = 12°C

8.85

6.32

Cdh Tj = +12 °C

0.988

0.990

Pdh Tj = Tbiv

13.46 kW

13.37 kW

COP Tj = Tbiv

3.21

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.58 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.51

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

12 W

12 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.40 kW

5.60 kW

Annual energy consumption Qhe

6258 kWh

8479 kWh

LWH-F15HVZPN9
Configure model
Model name
LWH-F15HVZPN9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.00 kW

15.00 kW

El input

3.33 kW

5.00 kW

COP

4.50

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

142 %

Prated

15.00 kW

15.00 kW

SCOP

4.96

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.90 kW

13.87 kW

COP Tj = -7°C

3.23

2.41

Cdh Tj = -7 °C

0.997

0.997

Pdh Tj = +2°C

8.53 kW

8.11 kW

COP Tj = +2°C

4.76

3.40

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

7.84 kW

7.96 kW

COP Tj = +7°C

6.55

4.97

Cdh Tj = +7 °C

0.987

0.991

Pdh Tj = 12°C

9.31 kW

8.22 kW

COP Tj = 12°C

9.05

6.27

Cdh Tj = +12 °C

0.985

0.989

Pdh Tj = Tbiv

13.90 kW

13.87 kW

COP Tj = Tbiv

3.23

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.09 kW

10.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.60

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.90 kW

4.50 kW

Annual energy consumption Qhe

6247 kWh

8565 kWh