1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.4 kW
7.8 kW
El input
1.68 kW
2.44 kW
COP
5.00
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
259.00 %
184.00 %
Prated
8.2 kW
8.3 kW
SCOP
6.56
4.68
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
8.20 kW
7.99 kW
COP Tj = +2°C
3.59
2.54
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.27 kW
5.36 kW
COP Tj = +7°C
6.03
4.15
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.46 kW
4.21 kW
COP Tj = 12°C
8.58
6.35
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.27 kW
5.36 kW
COP Tj = Tbiv
6.03
4.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.27 kW
7.99 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.54
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.30 kW
Annual energy consumption Qhe
1669.00 kWh
2368.00 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
135 %
Prated
6.8 kW
7.0 kW
SCOP
4.44
3.46
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
4.11 kW
4.49 kW
COP Tj = -7°C
3.97
2.87
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.18 kW
3.07 kW
COP Tj = +2°C
5.60
4.38
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.90 kW
3.67 kW
COP Tj = +7°C
6.46
5.58
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.43 kW
4.36 kW
COP Tj = 12°C
8.67
7.22
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.48 kW
5.69 kW
COP Tj = Tbiv
2.73
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.64 kW
5.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.54
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.15 kW
1.92 kW
Annual energy consumption Qhe
3772.00 kWh
4992.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.48
5.69
COP Tj = -15°C (if TOL<-20°C)
2.73
2.09
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
149 %
Prated
8.00 kW
6.80 kW
SCOP
5.19
3.82
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.09 kW
5.97 kW
COP Tj = -7°C
3.06
2.37
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.53 kW
3.71 kW
COP Tj = +2°C
5.10
3.85
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.96 kW
3.62 kW
COP Tj = +7°C
7.47
5.12
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.51 kW
4.31 kW
COP Tj = 12°C
9.66
6.77
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.09 kW
5.97 kW
COP Tj = Tbiv
3.06
2.37
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.97 kW
6.46 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
14 W
14 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.03 kW
0.34 kW
Annual energy consumption Qhe
3184 kWh
3676 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.0 kW
9.5 kW
El input
2.13 kW
3.11 kW
COP
4.70
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
281.00 %
188.00 %
Prated
8.6 kW
8.8 kW
SCOP
7.11
4.79
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
8.60 kW
8.54 kW
COP Tj = +2°C
3.62
2.50
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
5.52 kW
5.68 kW
COP Tj = +7°C
6.26
4.20
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.61 kW
4.29 kW
COP Tj = 12°C
9.84
6.53
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.52 kW
5.68 kW
COP Tj = Tbiv
6.26
4.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.61 kW
8.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.62
2.50
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.26 kW
Annual energy consumption Qhe
1614.00 kWh
2456.00 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
136 %
Prated
7.9 kW
8.0 kW
SCOP
4.54
3.49
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
4.89 kW
4.86 kW
COP Tj = -7°C
3.74
2.90
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.07 kW
3.09 kW
COP Tj = +2°C
5.66
4.38
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.83 kW
3.76 kW
COP Tj = +7°C
7.63
5.64
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.46 kW
4.32 kW
COP Tj = 12°C
9.24
6.92
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
6.42 kW
6.55 kW
COP Tj = Tbiv
2.69
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.39 kW
5.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.57
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.48 kW
2.20 kW
Annual energy consumption Qhe
4269.00 kWh
5659.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.42
6.55
COP Tj = -15°C (if TOL<-20°C)
2.69
1.99
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
149 %
Prated
9.2 kW
7.8 kW
SCOP
5.07
3.82
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
8.11 kW
6.88 kW
COP Tj = -7°C
2.84
2.31
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
5.10 kW
4.23 kW
COP Tj = +2°C
4.96
3.80
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.96 kW
3.62 kW
COP Tj = +7°C
7.47
5.21
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
4.48 kW
4.31 kW
COP Tj = 12°C
9.56
6.86
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
8.11 kW
6.88 kW
COP Tj = Tbiv
2.84
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.50 kW
7.42 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.99
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
0.35 kW
Annual energy consumption Qhe
3744 kWh
4215 kWh