0,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.5 kW
4.6 kW
El input
0.87 kW
1.44 kW
COP
5.15
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
235.00 %
170.00 %
Prated
4.6 kW
4.7 kW
SCOP
5.97
4.34
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
4.47 kW
4.61 kW
COP Tj = +2°C
4.08
2.69
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.97 kW
3.08 kW
COP Tj = +7°C
5.78
3.91
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.05 kW
2.94 kW
COP Tj = 12°C
7.64
5.85
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
2.97 kW
3.08 kW
COP Tj = Tbiv
5.78
3.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.47 kW
4.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.08
2.69
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.09 kW
Annual energy consumption Qhe
1024.00 kWh
1446.00 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
124 %
Prated
5.0 kW
4.3 kW
SCOP
4.03
3.18
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
3.02 kW
2.60 kW
COP Tj = -7°C
3.54
2.75
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.20 kW
2.11 kW
COP Tj = +2°C
4.89
3.91
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.61 kW
2.47 kW
COP Tj = +7°C
6.60
5.04
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.86 kW
2.77 kW
COP Tj = 12°C
7.03
6.14
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
4.08 kW
3.51 kW
COP Tj = Tbiv
2.56
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.40 kW
2.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.43
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.34 kW
Annual energy consumption Qhe
3056.00 kWh
3328.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.08
3.51
COP Tj = -15°C (if TOL<-20°C)
2.56
2.11
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
148 %
Prated
5.00 kW
4.90 kW
SCOP
5.07
3.79
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.45 kW
4.36 kW
COP Tj = -7°C
3.39
2.60
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.75 kW
2.65 kW
COP Tj = +2°C
5.04
3.75
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.72 kW
2.57 kW
COP Tj = +7°C
6.72
4.97
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.14 kW
3.04 kW
COP Tj = 12°C
8.52
6.55
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.45 kW
4.36 kW
COP Tj = Tbiv
3.39
2.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.00 kW
4.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
14 W
14 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.57 kW
Annual energy consumption Qhe
2034 kWh
2668 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.2 kW
6.2 kW
El input
1.27 kW
2.00 kW
COP
4.90
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
242.00 %
179.00 %
Prated
5.5 kW
6.0 kW
SCOP
6.14
4.55
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
5.48 kW
5.96 kW
COP Tj = +2°C
3.87
2.59
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.57 kW
3.89 kW
COP Tj = +7°C
5.77
4.00
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.03 kW
2.99 kW
COP Tj = 12°C
7.67
6.05
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
3.57 kW
3.89 kW
COP Tj = Tbiv
5.77
4.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.48 kW
5.96 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.87
2.59
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9 W
9 W
PCK
0.00 W
0.00 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.02 kW
0.04 kW
Annual energy consumption Qhe
1198.00 kWh
1762.00 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
132 %
Prated
6.3 kW
5.9 kW
SCOP
4.24
3.38
Tbiv
-15.00 °C
-15.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
3.90 kW
3.56 kW
COP Tj = -7°C
3.71
2.89
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.34 kW
2.28 kW
COP Tj = +2°C
5.15
4.12
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.69 kW
2.55 kW
COP Tj = +7°C
6.85
5.31
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.91 kW
2.82 kW
COP Tj = 12°C
7.46
6.22
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.15 kW
4.94 kW
COP Tj = Tbiv
2.56
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.96 kW
3.44 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.95
1.44
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14 W
14 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.35 kW
2.48 kW
Annual energy consumption Qhe
3663.00 kWh
4325.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.15
4.94
COP Tj = -15°C (if TOL<-20°C)
2.56
2.08
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
149 %
Prated
6.4 kW
5.9 kW
SCOP
4.89
3.82
Tbiv
-7 °C
-7 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
5.75 kW
5.36 kW
COP Tj = -7°C
3.10
2.41
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.71 kW
3.12 kW
COP Tj = +2°C
4.73
3.73
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.72 kW
2.62 kW
COP Tj = +7°C
6.92
5.21
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
3.15 kW
3.03 kW
COP Tj = 12°C
8.65
6.78
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
5.75 kW
5.36 kW
COP Tj = Tbiv
3.10
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.50 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.15
WTOL
75.00 °C
75.00 °C
Poff
9.00 W
9.00 W
PTO
14.00 W
14.00 W
PSB
9.00 W
9.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
0.75 kW
Annual energy consumption Qhe
2700 kWh
3191 kWh