1,180 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.18 kW
14.01 kW
El input
3.36 kW
4.54 kW
COP
4.52
3.08
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
141 %
Prated
13.77 kW
13.79 kW
SCOP
4.58
3.59
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
12.18 kW
12.20 kW
COP Tj = -7°C
2.99
2.26
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.43 kW
7.43 kW
COP Tj = +2°C
4.47
3.51
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.51 kW
5.88 kW
COP Tj = +7°C
6.21
4.81
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.40 kW
7.09 kW
COP Tj = 12°C
7.99
6.58
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.18 kW
12.20 kW
COP Tj = Tbiv
2.99
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.64 kW
13.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
63 W
63 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.25 kW
Annual energy consumption Qhe
6204 kWh
7934 kWh