1,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.98 kW
10.10 kW
El input
2.05 kW
3.29 kW
COP
4.88
3.07
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
145 %
Prated
12.03 kW
12.31 kW
SCOP
4.93
3.69
Tbiv
-7 °C
-7 °C
TOL
-27 °C
-27 °C
Pdh Tj = -7°C
10.64 kW
10.89 kW
COP Tj = -7°C
2.94
2.30
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.53 kW
6.66 kW
COP Tj = +2°C
4.74
3.53
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.30 kW
4.50 kW
COP Tj = +7°C
6.74
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.33 kW
4.05 kW
COP Tj = 12°C
9.68
7.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.64 kW
10.89 kW
COP Tj = Tbiv
2.94
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.67 kW
11.85 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
48 W
48 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.36 kW
0.45 kW
Annual energy consumption Qhe
5041 kWh
6881 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.06 kW
10.12 kW
El input
2.15 kW
3.31 kW
COP
4.67
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
144 %
Prated
11.61 kW
11.56 kW
SCOP
4.88
3.67
Tbiv
-7 °C
-7 °C
TOL
-27 °C
-27 °C
Pdh Tj = -7°C
10.27 kW
10.22 kW
COP Tj = -7°C
3.14
2.36
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.35 kW
6.23 kW
COP Tj = +2°C
4.62
3.52
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.13 kW
4.17 kW
COP Tj = +7°C
6.51
4.77
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.37 kW
4.07 kW
COP Tj = 12°C
9.37
6.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.27 kW
10.22 kW
COP Tj = Tbiv
3.14
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.01 kW
11.61 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
48 W
48 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
4915 kWh
6502 kWh