0,830 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.43 kW
2.33 kW
COP
4.88
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
199 %
153 %
Prated
7.20 kW
6.80 kW
SCOP
5.05
3.89
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.32 kW
5.97 kW
COP Tj = -7°C
3.25
2.33
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.02 kW
3.74 kW
COP Tj = +2°C
5.22
3.87
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.73 kW
2.73 kW
COP Tj = +7°C
6.85
5.19
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
1.60 kW
1.63 kW
COP Tj = 12°C
5.14
6.44
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
6.32 kW
5.97 kW
COP Tj = Tbiv
3.25
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.93 kW
5.59 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
7 W
7 W
PTO
25 W
25 W
PSB
7 W
7 W
PCK
27 W
27 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.22 kW
1.14 kW
Annual energy consumption Qhe
2928 kWh
3589 kWh