Certificate holders

Subtype

Hybrox 16

Certificate Holder
ait-deutschland GmbH
Industriestr. 3
95359 Kasendorf
Germany
Registration number
041-K001-54 / 01
Certification Body
BRE
Subtype title
Hybrox 16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,900 kg

Certification Date
24.06.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 14
Testing laboratory
Fraunhofer ISE, DE
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

alpha innotec Hybrox 16
Configure model
Model name
alpha innotec Hybrox 16
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.14 kW

4.94 kW

El input

1.12 kW

1.50 kW

COP

5.48

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

46 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

153 %

Prated

15.60 kW

15.25 kW

SCOP

4.95

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.47 kW

13.19 kW

COP Tj = -7°C

2.81

2.24

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.67 kW

8.30 kW

COP Tj = +2°C

4.93

3.82

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.69 kW

5.47 kW

COP Tj = +7°C

6.92

5.41

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

6.38 kW

6.17 kW

COP Tj = 12°C

7.92

6.39

Cdh Tj = +12 °C

0.970

0.983

Pdh Tj = Tbiv

13.47 kW

13.19 kW

COP Tj = Tbiv

2.81

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.38 kW

12.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

78 °C

78 °C

Poff

13 W

14 W

PTO

24 W

17 W

PSB

13 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.23 kW

3.06 kW

Annual energy consumption Qhe

6505 kWh

8089 kWh

NOVELAN Helox 16
Configure model
Model name
NOVELAN Helox 16
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.14 kW

4.94 kW

El input

1.12 kW

1.50 kW

COP

5.48

3.29

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

46 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

153 %

Prated

15.60 kW

15.25 kW

SCOP

4.95

3.89

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.47 kW

13.19 kW

COP Tj = -7°C

2.81

2.24

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.67 kW

8.30 kW

COP Tj = +2°C

4.93

3.82

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.69 kW

5.47 kW

COP Tj = +7°C

6.92

5.41

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

6.38 kW

6.17 kW

COP Tj = 12°C

7.92

6.39

Cdh Tj = +12 °C

0.970

0.983

Pdh Tj = Tbiv

13.47 kW

13.19 kW

COP Tj = Tbiv

2.81

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.38 kW

12.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

78 °C

78 °C

Poff

13 W

14 W

PTO

24 W

17 W

PSB

13 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.23 kW

3.06 kW

Annual energy consumption Qhe

6505 kWh

8089 kWh