Certificate holders

Subtype

VIESSMANN Vitocal 262-A R290 (300 L)

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0775
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
VIESSMANN Vitocal 262-A R290 (300 L)
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R290
Mass of Refrigerant

0,150 kg

Certification Date
19.03.2024
Testing basis
HP KEYMARK certification scheme rules V13
Generate PDF Export model CSV
  • Number of models 4

Models

VIESSMANN Vitocal 262-A Typ T2E - Outdoor air
Configure model
Model name
VIESSMANN Vitocal 262-A Typ T2E - Outdoor air
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
Yes

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

47 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

139 %

COP

3.39

Heating up time

13:22 h:min

Standby power input

23.0 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

396 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

VIESSMANN Vitocal 262-A Typ T2H - Outdoor air
Configure model
Model name
VIESSMANN Vitocal 262-A Typ T2H - Outdoor air
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
Yes

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

47 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

139 %

COP

3.39

Heating up time

13:22 h:min

Standby power input

23.0 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

396 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

VIESSMANN Vitocal 262-A Typ T2E - Indoor air
Configure model
Model name
VIESSMANN Vitocal 262-A Typ T2E - Indoor air
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Indoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
Yes

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

166 %

COP

4.03

Heating up time

10:22 h:min

Standby power input

23.0 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

424 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

VIESSMANN Vitocal 262-A Typ T2H - Indoor air
Configure model
Model name
VIESSMANN Vitocal 262-A Typ T2H - Indoor air
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Indoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
Yes

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

55 dB(A)

EN 16147

Declared load profile

XL

Efficiency ηDHW

166 %

COP

4.03

Heating up time

10:22 h:min

Standby power input

23.0 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

424 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed