0,900 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.90 kW
6.21 kW
El input
1.06 kW
2.20 kW
COP
4.60
2.83
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
153 %
Prated
6.70 kW
6.24 kW
SCOP
5.65
4.01
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.24 kW
COP Tj = +2°C
4.44
2.82
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
4.30 kW
4.01 kW
COP Tj = +7°C
5.47
3.61
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.54 kW
2.40 kW
COP Tj = 12°C
6.24
4.77
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1583 kWh
2076 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
156 %
Prated
6.70 kW
6.24 kW
SCOP
5.87
4.10
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.05 kW
3.77 kW
COP Tj = -7°C
5.68
3.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.47 kW
2.30 kW
COP Tj = +2°C
6.28
4.38
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.54 kW
2.41 kW
COP Tj = +7°C
6.30
4.93
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.53 kW
2.44 kW
COP Tj = 12°C
6.17
5.17
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2810 kWh
3748 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
156 %
Prated
6.70 kW
6.24 kW
SCOP
5.57
4.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
5.52 kW
COP Tj = -7°C
4.73
3.12
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.61 kW
3.36 kW
COP Tj = +2°C
5.70
4.10
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.32 kW
2.16 kW
COP Tj = +7°C
5.96
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.54 kW
2.16 kW
COP Tj = 12°C
6.28
5.05
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2485 kWh
3139 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
Efficiency ηDHW
%
COP
Heating up time
h:min
Standby power input
W
Reference hot water temperature
°C
Mixed water at 40°C
l
Colder Climate
EN 16147
Declared load profile
Efficiency ηDHW
%
COP
Heating up time
h:min
Standby power input
W
Reference hot water temperature
°C
Mixed water at 40°C
l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
127 %
COP
3.14
Heating up time
02:13 h:min
Standby power input
25.0 W
Reference hot water temperature
52.2 °C
Mixed water at 40°C
234 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
8.88 kW
8.39 kW
El input
1.53 kW
2.36 kW
COP
5.82
3.56
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
308 %
207 %
Prated
8.86 kW
8.28 kW
SCOP
7.90
5.38
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.86 kW
8.28 kW
COP Tj = +2°C
5.91
3.62
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.70 kW
5.33 kW
COP Tj = +7°C
7.54
4.79
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.38 kW
3.24 kW
COP Tj = 12°C
8.97
6.53
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1499 kWh
2058 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
327 %
218 %
Prated
8.86 kW
8.28 kW
SCOP
8.38
5.65
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.36 kW
5.01 kW
COP Tj = -7°C
8.01
5.10
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.27 kW
3.05 kW
COP Tj = +2°C
9.12
6.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.38 kW
3.26 kW
COP Tj = +7°C
9.10
6.80
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.37 kW
3.30 kW
COP Tj = 12°C
8.84
7.19
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2606 kWh
3613 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
309 %
208 %
Prated
8.86 kW
8.28 kW
SCOP
7.93
5.41
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.84 kW
7.33 kW
COP Tj = -7°C
6.21
3.96
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.77 kW
4.46 kW
COP Tj = +2°C
8.15
5.46
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
3.07 kW
3.22 kW
COP Tj = +7°C
8.96
6.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.38 kW
3.27 kW
COP Tj = 12°C
9.07
6.89
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2310 kWh
3165 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.90 kW
6.21 kW
El input
1.06 kW
2.20 kW
COP
4.60
2.83
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
153 %
Prated
6.70 kW
6.24 kW
SCOP
5.65
4.01
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.70 kW
6.24 kW
COP Tj = +2°C
4.44
2.82
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
4.30 kW
4.01 kW
COP Tj = +7°C
5.47
3.61
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
2.54 kW
2.40 kW
COP Tj = 12°C
6.24
4.77
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1583 kWh
2076 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
227 %
156 %
Prated
6.70 kW
6.24 kW
SCOP
5.87
4.10
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.05 kW
3.77 kW
COP Tj = -7°C
5.68
3.81
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.47 kW
2.30 kW
COP Tj = +2°C
6.28
4.38
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.54 kW
2.41 kW
COP Tj = +7°C
6.30
4.93
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.53 kW
2.44 kW
COP Tj = 12°C
6.17
5.17
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2810 kWh
3748 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
33 dB(A)
33 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
215 %
156 %
Prated
6.70 kW
6.24 kW
SCOP
5.57
4.10
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.92 kW
5.52 kW
COP Tj = -7°C
4.73
3.12
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.61 kW
3.36 kW
COP Tj = +2°C
5.70
4.10
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
2.32 kW
2.16 kW
COP Tj = +7°C
5.96
4.80
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.54 kW
2.16 kW
COP Tj = 12°C
6.28
5.05
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
6.70 kW
6.24 kW
COP Tj = Tbiv
4.44
2.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.70 kW
6.24 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.44
2.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2485 kWh
3139 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
Efficiency ηDHW
%
COP
Heating up time
h:min
Standby power input
W
Reference hot water temperature
°C
Mixed water at 40°C
l
Colder Climate
EN 16147
Declared load profile
Efficiency ηDHW
%
COP
Heating up time
h:min
Standby power input
W
Reference hot water temperature
°C
Mixed water at 40°C
l
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
91 %
COP
2.16
Heating up time
02:02 h:min
Standby power input
25.3 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
217 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
8.88 kW
8.39 kW
El input
1.53 kW
2.36 kW
COP
5.82
3.56
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
308 %
207 %
Prated
8.86 kW
8.28 kW
SCOP
7.90
5.38
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.86 kW
8.28 kW
COP Tj = +2°C
5.91
3.62
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
5.70 kW
5.33 kW
COP Tj = +7°C
7.54
4.79
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
3.38 kW
3.24 kW
COP Tj = 12°C
8.97
6.53
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1499 kWh
2058 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
327 %
218 %
Prated
8.86 kW
8.28 kW
SCOP
8.38
5.65
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.36 kW
5.01 kW
COP Tj = -7°C
8.01
5.10
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
3.27 kW
3.05 kW
COP Tj = +2°C
9.12
6.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
3.38 kW
3.26 kW
COP Tj = +7°C
9.10
6.80
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.37 kW
3.30 kW
COP Tj = 12°C
8.84
7.19
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2606 kWh
3613 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
309 %
208 %
Prated
8.86 kW
8.28 kW
SCOP
7.93
5.41
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.84 kW
7.33 kW
COP Tj = -7°C
6.21
3.96
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
4.77 kW
4.46 kW
COP Tj = +2°C
8.15
5.46
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
3.07 kW
3.22 kW
COP Tj = +7°C
8.96
6.33
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
3.38 kW
3.27 kW
COP Tj = 12°C
9.07
6.89
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
8.86 kW
8.28 kW
COP Tj = Tbiv
5.91
3.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.86 kW
8.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.91
3.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2310 kWh
3165 kWh