7,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
21.50 kW
17.60 kW
El input
4.76 kW
6.64 kW
COP
4.52
2.62
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
126 %
Prated
14.28 kW
14.49 kW
SCOP
4.41
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.63 kW
11.86 kW
COP Tj = -7°C
2.56
2.02
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
10.50 kW
9.50 kW
COP Tj = +2°C
4.72
3.20
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
12.42 kW
11.10 kW
COP Tj = +7°C
5.65
4.40
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
14.75 kW
13.45 kW
COP Tj = 12°C
7.42
6.15
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
12.63 kW
12.26 kW
COP Tj = Tbiv
2.56
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.39 kW
8.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.33
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
50 W
50 W
PTO
100 W
100 W
PSB
50 W
50 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.89 kW
5.86 kW
Annual energy consumption Qhe
6681 kWh
9272 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
24.30 kW
19.70 kW
El input
5.54 kW
7.70 kW
COP
4.40
2.56
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
71 dB(A)
71 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
172 %
126 %
Prated
17.18 kW
15.92 kW
SCOP
4.38
3.23
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
15.20 kW
13.03 kW
COP Tj = -7°C
2.50
1.98
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
10.57 kW
9.50 kW
COP Tj = +2°C
4.62
3.20
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
12.50 kW
11.47 kW
COP Tj = +7°C
2.60
4.41
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
14.82 kW
13.80 kW
COP Tj = 12°C
7.32
6.14
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
15.20 kW
13.47 kW
COP Tj = Tbiv
2.50
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.41 kW
9.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
1.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
50 W
50 W
PTO
100 W
100 W
PSB
50 W
50 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.77 kW
6.83 kW
Annual energy consumption Qhe
8100 kWh
10191 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
26.90 kW
21.80 kW
El input
6.17 kW
8.27 kW
COP
4.35
2.64
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
72 dB(A)
72 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
171 %
126 %
Prated
19.55 kW
17.21 kW
SCOP
4.35
3.22
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.29 kW
14.09 kW
COP Tj = -7°C
2.38
1.97
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
10.68 kW
9.31 kW
COP Tj = +2°C
4.59
3.19
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
12.52 kW
11.10 kW
COP Tj = +7°C
5.60
4.40
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
14.85 kW
13.45 kW
COP Tj = 12°C
7.30
6.15
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
17.29 kW
14.56 kW
COP Tj = Tbiv
2.38
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.06 kW
10.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.32
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
50 W
50 W
PTO
100 W
100 W
PSB
50 W
50 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
3.49 kW
7.00 kW
Annual energy consumption Qhe
9282 kWh
11062 kWh
Heating
EN 14511-2
Heat output
21.10 kW
El input
4.86 kW
COP
4.35
Average Climate
EN 12102-1
Sound power level indoor
72 dB(A)
Sound power level outdoor
72 dB(A)
EN 14825
ηs
164 %
Prated
15.95 kW
SCOP
4.18
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
14.11 kW
COP Tj = -7°C
2.60
Cdh Tj = -7 °C
0.980
Pdh Tj = +2°C
10.50 kW
COP Tj = +2°C
4.48
Cdh Tj = +2 °C
0.980
Pdh Tj = +7°C
12.42 kW
COP Tj = +7°C
5.30
Cdh Tj = +7 °C
0.980
Pdh Tj = 12°C
14.75 kW
COP Tj = 12°C
6.51
Cdh Tj = +12 °C
0.980
Pdh Tj = Tbiv
14.11 kW
COP Tj = Tbiv
2.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
WTOL
35 °C
Poff
50 W
PTO
100 W
PSB
50 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
2.88 kW
Annual energy consumption Qhe
7886 kWh
Heating
EN 14511-2
Heat output
24.50 kW
El input
5.79 kW
COP
4.24
Average Climate
EN 12102-1
Sound power level outdoor
73 dB(A)
EN 14825
ηs
162 %
Prated
18.60 kW
SCOP
4.12
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
16.44 kW
COP Tj = -7°C
2.43
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
11.20 kW
COP Tj = +2°C
4.38
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
12.42 kW
COP Tj = +7°C
5.30
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
14.75 kW
COP Tj = 12°C
6.51
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
16.44 kW
COP Tj = Tbiv
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.36 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
50 W
PTO
100 W
PSB
50 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
3.22 kW
Annual energy consumption Qhe
9320 kWh
Heating
EN 14511-2
Heat output
27.50 kW
El input
6.51 kW
COP
4.22
Average Climate
EN 12102-1
Sound power level outdoor
73 dB(A)
EN 14825
ηs
159 %
Prated
20.60 kW
SCOP
4.05
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
18.20 kW
COP Tj = -7°C
2.30
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
12.00 kW
COP Tj = +2°C
4.28
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
12.52 kW
COP Tj = +7°C
5.22
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
14.85 kW
COP Tj = 12°C
6.51
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
18.20 kW
COP Tj = Tbiv
2.30
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
17.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.28
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
50 W
PTO
100 W
PSB
50 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
3.48 kW
Annual energy consumption Qhe
10501 kWh