Certificate holders

Subtype

Chappée ERIA S PLUS DUO R32 12-16

Certificate Holder
BDR Thermea FR (CHAPPEE)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
24.03.012
Certification Body
ECC Eurovent Certita Certification
Subtype title
Chappée ERIA S PLUS DUO R32 12-16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,840 kg

Certification Date
19.03.2024
Testing basis
EN 14511: 2018 / EN 14825: 2018 / EN 16147: 2017 / EN 12102-1: 2017
Testing laboratory
BDR Thermea France
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

ERIA S PLUS DUO R32 12 MR/EM
Configure model
Model name
ERIA S PLUS DUO R32 12 MR/EM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.17 kW

5.2 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

142 %

Prated

12.1 kW

12.1 kW

SCOP

4.68

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.84 kW

10.2 kW

COP Tj = -7°C

2.96

2.13

Cdh Tj = -7 °C

0.9

1

Pdh Tj = +2°C

6.31 kW

6.15 kW

COP Tj = +2°C

4.36

3.49

Cdh Tj = +2 °C

0.9

1

Pdh Tj = +7°C

4.31 kW

4.31 kW

COP Tj = +7°C

6.5

4.97

Cdh Tj = +7 °C

0.9

1

Pdh Tj = 12°C

3.64 kW

3.2 kW

COP Tj = 12°C

8.9

6.97

Cdh Tj = +12 °C

0.9

0.98

Pdh Tj = Tbiv

10.84 kW

10.2 kW

COP Tj = Tbiv

2.96

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.24 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

1

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.69 kW

Annual energy consumption Qhe

5336 kWh

6871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 12 MR/HM
Configure model
Model name
ERIA S PLUS DUO R32 12 MR/HM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.17 kW

5.2 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

142 %

Prated

12.1 kW

12.1 kW

SCOP

4.68

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.84 kW

10.2 kW

COP Tj = -7°C

2.96

2.13

Cdh Tj = -7 °C

0.9

1

Pdh Tj = +2°C

6.31 kW

6.15 kW

COP Tj = +2°C

4.36

3.49

Cdh Tj = +2 °C

0.9

1

Pdh Tj = +7°C

4.31 kW

4.31 kW

COP Tj = +7°C

6.5

4.97

Cdh Tj = +7 °C

0.9

1

Pdh Tj = 12°C

3.64 kW

3.2 kW

COP Tj = 12°C

8.9

6.97

Cdh Tj = +12 °C

0.9

0.98

Pdh Tj = Tbiv

10.84 kW

10.2 kW

COP Tj = Tbiv

2.96

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.24 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

1

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.69 kW

Annual energy consumption Qhe

5336 kWh

6871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 12 TR/ET
Configure model
Model name
ERIA S PLUS DUO R32 12 TR/ET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.17 kW

5.2 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

142 %

Prated

12.1 kW

12.1 kW

SCOP

4.68

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.84 kW

10.2 kW

COP Tj = -7°C

2.96

2.13

Cdh Tj = -7 °C

0.9

1

Pdh Tj = +2°C

6.31 kW

6.15 kW

COP Tj = +2°C

4.36

3.49

Cdh Tj = +2 °C

0.9

1

Pdh Tj = +7°C

4.31 kW

4.31 kW

COP Tj = +7°C

6.5

4.97

Cdh Tj = +7 °C

0.9

1

Pdh Tj = 12°C

3.64 kW

3.2 kW

COP Tj = 12°C

8.9

6.97

Cdh Tj = +12 °C

0.9

0.98

Pdh Tj = Tbiv

10.84 kW

10.2 kW

COP Tj = Tbiv

2.96

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.24 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

1

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.69 kW

Annual energy consumption Qhe

5336 kWh

6871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 12 TR/HT
Configure model
Model name
ERIA S PLUS DUO R32 12 TR/HT
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.1 kW

12 kW

El input

2.44 kW

3.87 kW

COP

4.95

3.1

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

10.55 kW

10.77 kW

Cooling capacity

4.19

2.92

EER

2.52

3.69

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

10.55 kW

10.77 kW

SEER

4.09

6.66

Pdc Tj = 35°C

10.55 kW

10.77 kW

EER Tj = 35°C

2.52

3.69

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

7.78 kW

7.88 kW

EER Tj = 30°C

3.58

5.39

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.17 kW

5.2 kW

EER Tj = 25°C

4.57

7.93

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.24 kW

3.03 kW

EER Tj = 20°C

5.05

9.28

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1548 kWh

971 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

142 %

Prated

12.1 kW

12.1 kW

SCOP

4.68

3.62

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.84 kW

10.2 kW

COP Tj = -7°C

2.96

2.13

Cdh Tj = -7 °C

0.9

1

Pdh Tj = +2°C

6.31 kW

6.15 kW

COP Tj = +2°C

4.36

3.49

Cdh Tj = +2 °C

0.9

1

Pdh Tj = +7°C

4.31 kW

4.31 kW

COP Tj = +7°C

6.5

4.97

Cdh Tj = +7 °C

0.9

1

Pdh Tj = 12°C

3.64 kW

3.2 kW

COP Tj = 12°C

8.9

6.97

Cdh Tj = +12 °C

0.9

0.98

Pdh Tj = Tbiv

10.84 kW

10.2 kW

COP Tj = Tbiv

2.96

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.24 kW

9.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.54

1.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

1

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.69 kW

Annual energy consumption Qhe

5336 kWh

6871 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 16 MR/EM
Configure model
Model name
ERIA S PLUS DUO R32 16 MR/EM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.56 kW

5.52 kW

COP

4.5

2.9

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.2

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

9.4 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.8

7.78

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.8

6.89

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1766 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

142 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.55

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7442 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 16 MR/HM
Configure model
Model name
ERIA S PLUS DUO R32 16 MR/HM
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.56 kW

5.52 kW

COP

4.5

2.9

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.2

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

9.4 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.8

7.78

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.8

6.89

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1766 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

142 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.55

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7442 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 16 TR/ET
Configure model
Model name
ERIA S PLUS DUO R32 16 TR/ET
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.56 kW

5.52 kW

COP

4.5

2.9

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.2

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

9.4 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.8

7.78

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.8

6.89

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1766 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

142 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.55

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7442 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l

ERIA S PLUS DUO R32 16 TR/HT
Configure model
Model name
ERIA S PLUS DUO R32 16 TR/HT
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16 kW

16 kW

El input

3.56 kW

5.52 kW

COP

4.5

2.9

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

12.36 kW

11.63 kW

Cooling capacity

5.44

3.22

EER

2.27

3.61

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.36 kW

11.63 kW

SEER

4.2

6.19

Pdc Tj = 35°C

12.36 kW

11.63 kW

EER Tj = 35°C

2.27

3.61

Cdc Tj = 35 °C

0.9

0.9

Pdc Tj = 30°C

9.4 kW

8.67 kW

EER Tj = 30°C

3.41

5.22

Cdc Tj = 30 °C

0.9

0.9

Pdc Tj = 25°C

5.89 kW

5.39 kW

EER Tj = 25°C

4.8

7.78

Cdc Tj = 25 °C

0.9

0.9

Pdc Tj = 20°C

2.81 kW

2.48 kW

EER Tj = 20°C

5.8

6.89

Cdc Tj = 20 °C

0.9

0.9

Poff

14 W

14 W

PTO

10 W

10 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1766 kWh

1128 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

39 dB(A)

39 dB(A)

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

142 %

Prated

15.21 kW

13.02 kW

SCOP

4.50

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.45 kW

11.52 kW

COP Tj = -7°C

2.72

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.20 kW

7.18 kW

COP Tj = +2°C

4.30

3.55

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.70 kW

4.56 kW

COP Tj = +7°C

6.20

4.90

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.78 kW

3.32 kW

COP Tj = 12°C

8.51

6.17

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.45 kW

11.52 kW

COP Tj = Tbiv

2.72

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.52 kW

10.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.48

1.91

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.67 kW

Annual energy consumption Qhe

6979 kWh

7442 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

108 %

COP

2.6

Heating up time

00:57 h:min

Standby power input

32.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

239 l