Ecodan Zubadan 23

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0057-20 / rev. 2
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Ecodan Zubadan 23
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

7,700 kg

Certification Date
09.04.2020
Testing basis
HP Keymark scheme rules rev. no. 7
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

PUHZ-SHW230YKA2(-BS) + EHSE-*M*D
Configure model
Model name
PUHZ-SHW230YKA2(-BS) + EHSE-*M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

23 kW

23 kW

El input

6.3 kW

9.31 kW

COP

3.65

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

127 %

Prated

25 kW

23 kW

SCOP

4.18

3.25

Tbiv

-10 °C

-10 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

22.1 kW

20.3 kW

COP Tj = -7°C

3.4

2.1

Cdh Tj = -7 °C

0.98

1

Pdh Tj = +2°C

13.5 kW

12.4 kW

COP Tj = +2°C

3.8

3.02

Cdh Tj = +2 °C

0.95

1

Pdh Tj = +7°C

12 kW

11.2 kW

COP Tj = +7°C

5.32

4.54

Cdh Tj = +7 °C

0.95

0.99

Pdh Tj = 12°C

14.6 kW

13.7 kW

COP Tj = 12°C

6.68

5.79

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

25 kW

23 kW

COP Tj = Tbiv

2.19

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25 kW

23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.85

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

12351 kWh

14615 kWh

PUHZ-SHW230YKA2(-BS) + EHSE-M*D
Configure model
Model name
PUHZ-SHW230YKA2(-BS) + EHSE-M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

23 kW

23 kW

El input

6.3 kW

9.31 kW

COP

3.65

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

164 %

127 %

Prated

25 kW

23 kW

SCOP

4.18

3.25

Tbiv

-10 °C

-10 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

22.1 kW

20.3 kW

COP Tj = -7°C

3.4

2.1

Cdh Tj = -7 °C

0.98

1

Pdh Tj = +2°C

13.5 kW

12.4 kW

COP Tj = +2°C

3.8

3.02

Cdh Tj = +2 °C

0.95

1

Pdh Tj = +7°C

12 kW

11.2 kW

COP Tj = +7°C

5.32

4.54

Cdh Tj = +7 °C

0.95

0.99

Pdh Tj = 12°C

14.6 kW

13.7 kW

COP Tj = 12°C

6.68

5.79

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

25 kW

23 kW

COP Tj = Tbiv

2.19

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25 kW

23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.85

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

12351 kWh

14615 kWh

PUHZ-SHW230YKA2(-BS) + ERSE-*M*D
Configure model
Model name
PUHZ-SHW230YKA2(-BS) + ERSE-*M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

23 kW

23 kW

El input

6.3 kW

9.31 kW

COP

3.65

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

128 %

Prated

25 kW

23 kW

SCOP

4.21

3.28

Tbiv

-10 °C

-10 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

22.1 kW

20.3 kW

COP Tj = -7°C

3.4

2.1

Cdh Tj = -7 °C

0.98

1

Pdh Tj = +2°C

13.5 kW

12.4 kW

COP Tj = +2°C

3.8

3.04

Cdh Tj = +2 °C

0.95

1

Pdh Tj = +7°C

12 kW

11.2 kW

COP Tj = +7°C

5.32

4.54

Cdh Tj = +7 °C

0.95

0.99

Pdh Tj = 12°C

14.6 kW

13.7 kW

COP Tj = 12°C

6.68

5.79

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

25 kW

23 kW

COP Tj = Tbiv

2.19

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25 kW

23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.85

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

12270 kWh

14485 kWh

PUHZ-SHW230YKA2(-BS) + ERSE-M*D
Configure model
Model name
PUHZ-SHW230YKA2(-BS) + ERSE-M*D
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

23 kW

23 kW

El input

6.3 kW

9.31 kW

COP

3.65

2.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

75 dB(A)

75 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

165 %

128 %

Prated

25 kW

23 kW

SCOP

4.21

3.28

Tbiv

-10 °C

-10 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

22.1 kW

20.3 kW

COP Tj = -7°C

3.4

2.1

Cdh Tj = -7 °C

0.98

1

Pdh Tj = +2°C

13.5 kW

12.4 kW

COP Tj = +2°C

3.8

3.04

Cdh Tj = +2 °C

0.95

1

Pdh Tj = +7°C

12 kW

11.2 kW

COP Tj = +7°C

5.32

4.54

Cdh Tj = +7 °C

0.95

0.99

Pdh Tj = 12°C

14.6 kW

13.7 kW

COP Tj = 12°C

6.68

5.79

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

25 kW

23 kW

COP Tj = Tbiv

2.19

1.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25 kW

23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.85

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

12270 kWh

14485 kWh