7,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
23 kW
23 kW
El input
6.3 kW
9.31 kW
COP
3.65
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
75 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
164 %
127 %
Prated
25 kW
23 kW
SCOP
4.18
3.25
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
22.1 kW
20.3 kW
COP Tj = -7°C
3.4
2.1
Cdh Tj = -7 °C
0.98
1
Pdh Tj = +2°C
13.5 kW
12.4 kW
COP Tj = +2°C
3.8
3.02
Cdh Tj = +2 °C
0.95
1
Pdh Tj = +7°C
12 kW
11.2 kW
COP Tj = +7°C
5.32
4.54
Cdh Tj = +7 °C
0.95
0.99
Pdh Tj = 12°C
14.6 kW
13.7 kW
COP Tj = 12°C
6.68
5.79
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
25 kW
23 kW
COP Tj = Tbiv
2.19
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
25 kW
23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.85
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12351 kWh
14615 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
23 kW
23 kW
El input
6.3 kW
9.31 kW
COP
3.65
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
75 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
164 %
127 %
Prated
25 kW
23 kW
SCOP
4.18
3.25
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
22.1 kW
20.3 kW
COP Tj = -7°C
3.4
2.1
Cdh Tj = -7 °C
0.98
1
Pdh Tj = +2°C
13.5 kW
12.4 kW
COP Tj = +2°C
3.8
3.02
Cdh Tj = +2 °C
0.95
1
Pdh Tj = +7°C
12 kW
11.2 kW
COP Tj = +7°C
5.32
4.54
Cdh Tj = +7 °C
0.95
0.99
Pdh Tj = 12°C
14.6 kW
13.7 kW
COP Tj = 12°C
6.68
5.79
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
25 kW
23 kW
COP Tj = Tbiv
2.19
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
25 kW
23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.85
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12351 kWh
14615 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
23 kW
23 kW
El input
6.3 kW
9.31 kW
COP
3.65
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
75 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
128 %
Prated
25 kW
23 kW
SCOP
4.21
3.28
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
22.1 kW
20.3 kW
COP Tj = -7°C
3.4
2.1
Cdh Tj = -7 °C
0.98
1
Pdh Tj = +2°C
13.5 kW
12.4 kW
COP Tj = +2°C
3.8
3.04
Cdh Tj = +2 °C
0.95
1
Pdh Tj = +7°C
12 kW
11.2 kW
COP Tj = +7°C
5.32
4.54
Cdh Tj = +7 °C
0.95
0.99
Pdh Tj = 12°C
14.6 kW
13.7 kW
COP Tj = 12°C
6.68
5.79
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
25 kW
23 kW
COP Tj = Tbiv
2.19
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
25 kW
23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.85
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12270 kWh
14485 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
23 kW
23 kW
El input
6.3 kW
9.31 kW
COP
3.65
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
45 dB(A)
45 dB(A)
Sound power level outdoor
75 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
128 %
Prated
25 kW
23 kW
SCOP
4.21
3.28
Tbiv
-10 °C
-10 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
22.1 kW
20.3 kW
COP Tj = -7°C
3.4
2.1
Cdh Tj = -7 °C
0.98
1
Pdh Tj = +2°C
13.5 kW
12.4 kW
COP Tj = +2°C
3.8
3.04
Cdh Tj = +2 °C
0.95
1
Pdh Tj = +7°C
12 kW
11.2 kW
COP Tj = +7°C
5.32
4.54
Cdh Tj = +7 °C
0.95
0.99
Pdh Tj = 12°C
14.6 kW
13.7 kW
COP Tj = 12°C
6.68
5.79
Cdh Tj = +12 °C
0.98
0.99
Pdh Tj = Tbiv
25 kW
23 kW
COP Tj = Tbiv
2.19
1.85
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
25 kW
23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.85
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
12270 kWh
14485 kWh