Subtype

ECO200

Certificate Holder
Energie est, Lda.
Zona Industrial de Laúndos, lote 48
4570-311, Laúndos Póvoa de Varzim
Portugal
Registration number
011-1W0350
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ECO200
Driving energy
Electricity
Heat Pump Type
Heat Pump for Domestic Hot Water (DHW)
Refrigerant
R134a
Mass of Refrigerant

1,300 kg

Certification Date
28.06.2024
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 14 (as of 2024-04)
Generate PDF Export model CSV
  • Number of models 3

Models

Eco 200i
Configure model
Model name
Eco 200i
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

123 %

COP

2.97

Heating up time

7:06 h:min

Standby power input

26.5 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

223 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

Eco 200ix
Configure model
Model name
Eco 200ix
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

123 %

COP

2.97

Heating up time

7:06 h:min

Standby power input

26.5 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

223 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

Eco 200esm
Configure model
Model name
Eco 200esm
Units
Indoor
Climate zone (for heating)
n/a
Heat Source
Outdoor Air
Any additional heat sources
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
No

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

123 %

COP

2.97

Heating up time

7:06 h:min

Standby power input

26.5 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

223 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed