0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
8.81 kW
9.21 kW
El input
1.95 kW
3.05 kW
COP
4.52
3.02
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
45 dB(A)
Sound power level outdoor
55 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
141 %
Prated
8.77 kW
8.65 kW
SCOP
4.70
3.61
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.75 kW
7.65 kW
COP Tj = -7°C
2.85
2.40
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.88 kW
4.85 kW
COP Tj = +2°C
4.76
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.23 kW
4.10 kW
COP Tj = +7°C
6.38
4.73
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.03 kW
4.93 kW
COP Tj = 12°C
8.45
6.46
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
7.75 kW
7.65 kW
COP Tj = Tbiv
2.85
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.22 kW
6.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.03
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
11 W
11 W
PTO
46 W
46 W
PSB
11 W
11 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.55 kW
2.03 kW
Annual energy consumption Qhe
3851 kWh
4955 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.79
Heating up time
1:41:26 h:min
Standby power input
26.0 W
Reference hot water temperature
43.8 °C
Mixed water at 40°C
149 l