0,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.70 kW
5.56 kW
El input
1.16 kW
1.69 kW
COP
4.93
3.29
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
45 dB(A)
Sound power level outdoor
57 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
144 %
Prated
6.76 kW
6.70 kW
SCOP
4.71
3.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.98 kW
5.92 kW
COP Tj = -7°C
3.13
2.50
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
3.81 kW
3.79 kW
COP Tj = +2°C
4.64
3.69
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.13 kW
2.82 kW
COP Tj = +7°C
6.30
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.82 kW
3.66 kW
COP Tj = 12°C
8.48
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
5.98 kW
5.92 kW
COP Tj = Tbiv
3.13
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.32 kW
5.35 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.87
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
12 W
12 W
PTO
41 W
41 W
PSB
12 W
12 W
PCK
30 W
30 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.44 kW
1.35 kW
Annual energy consumption Qhe
2970 kWh
3774 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
M
Efficiency ηDHW
71 %
COP
1.69
Heating up time
1:23:47 h:min
Standby power input
35.0 W
Reference hot water temperature
47.9 °C
Mixed water at 40°C
103 l