Air to Water Heat Pump- R290- 8kW

Certificate Holder
Aira Group AB
Norra Stationsgatan 93C
11364 Stockholm
Sweden
Registration number
041-K087-07
Certification Body
BRE Global Limited
Subtype title
Air to Water Heat Pump- R290- 8kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
11.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

HPO-AW-8-230V-1.0
Configure model
Model name
HPO-AW-8-230V-1.0
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.81 kW

9.21 kW

El input

1.95 kW

3.05 kW

COP

4.52

3.02

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

141 %

Prated

8.77 kW

8.65 kW

SCOP

4.70

3.61

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.75 kW

7.65 kW

COP Tj = -7°C

2.85

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.88 kW

4.85 kW

COP Tj = +2°C

4.76

3.58

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.23 kW

4.10 kW

COP Tj = +7°C

6.38

4.73

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.03 kW

4.93 kW

COP Tj = 12°C

8.45

6.46

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.75 kW

7.65 kW

COP Tj = Tbiv

2.85

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.22 kW

6.62 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.03

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

46 W

46 W

PSB

11 W

11 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.55 kW

2.03 kW

Annual energy consumption Qhe

3851 kWh

4955 kWh