Certificate holders

Subtype

Ecodan Power Inverter (TR) 6/8/10 + 170D AA

Certificate Holder
Mitsubishi Electric Air Conditioning Systems Europe LTD
Nettlehill Road, Houston Industrial Estate
EH54 5EQ Livingston
United Kingdom
Registration number
037-0114-23 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Ecodan Power Inverter (TR) 6/8/10 + 170D AA
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,800 kg

Certification Date
26.04.2023
Testing basis
HP Keymark scheme rules rev. no. 9
Generate PDF Export model CSV Download certificate
  • Number of models 12

Models

PUZ-SWM60VAA + EHST17D-*M*D
Configure model
Model name
PUZ-SWM60VAA + EHST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5 kW

4 kW

El input

1 kW

1.63 kW

COP

5

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.5 kW

1.14 kW

Cooling capacity

5.1

6

EER

3.4

5.25

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.1 kW

6 kW

SEER

3.88

5.91

Pdc Tj = 35°C

5.1 kW

6 kW

EER Tj = 35°C

3.4

5.25

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

3.76 kW

4.42 kW

EER Tj = 30°C

3.84

5.95

Cdc Tj = 30 °C

0.985

0.98

Pdc Tj = 25°C

2.42 kW

3.3 kW

EER Tj = 25°C

4.07

6.38

Cdc Tj = 25 °C

0.975

0.971

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.57

7

Cdc Tj = 20 °C

0.973

0.97

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

789 kWh

609 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

126 %

Prated

6 kW

6 kW

SCOP

4.59

3.23

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.31 kW

COP Tj = -7°C

3.38

2.27

Cdh Tj = -7 °C

0.991

0.994

Pdh Tj = +2°C

4.79 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

4.9 kW

4.1 kW

COP Tj = +7°C

5.61

3.99

Cdh Tj = +7 °C

0.983

0.985

Pdh Tj = 12°C

3 kW

2.7 kW

COP Tj = 12°C

6.19

5.58

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

6 kW

6 kW

COP Tj = Tbiv

2.74

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6 kW

6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.995

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2701 kWh

3834 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80VAA + EHST17D-*M*D
Configure model
Model name
PUZ-SWM80VAA + EHST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.12

5.74

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.993

0.991

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.989

0.986

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.98

0.976

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.972

0.971

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1034 kWh

836 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

129 %

Prated

8 kW

8 kW

SCOP

4.59

3.3

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.993

0.995

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.984

0.989

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.996

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3599 kWh

5016 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80YAA + EHST17D-*M*D
Configure model
Model name
PUZ-SWM80YAA + EHST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.06

5.62

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.984

0.979

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.97

0.965

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.959

0.958

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Annual energy consumption Qce

1051 kWh

853 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

128 %

Prated

8 kW

8 kW

SCOP

4.55

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.99

0.993

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.976

0.984

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.975

0.979

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.955

0.955

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.995

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3636 kWh

5053 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM60VAA + ERST17D-*M*D
Configure model
Model name
PUZ-SWM60VAA + ERST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5 kW

4 kW

El input

1 kW

1.63 kW

COP

5

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.5 kW

1.14 kW

Cooling capacity

5.1

6

EER

3.4

5.25

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.1 kW

6 kW

SEER

3.88

5.91

Pdc Tj = 35°C

5.1 kW

6 kW

EER Tj = 35°C

3.4

5.25

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

3.76 kW

4.42 kW

EER Tj = 30°C

3.84

5.95

Cdc Tj = 30 °C

0.985

0.98

Pdc Tj = 25°C

2.42 kW

3.3 kW

EER Tj = 25°C

4.07

6.38

Cdc Tj = 25 °C

0.975

0.971

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.57

7

Cdc Tj = 20 °C

0.973

0.97

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

789 kWh

609 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

128 %

Prated

6 kW

6 kW

SCOP

4.68

3.28

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.31 kW

COP Tj = -7°C

3.38

2.27

Cdh Tj = -7 °C

0.991

0.994

Pdh Tj = +2°C

4.79 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

4.9 kW

4.1 kW

COP Tj = +7°C

5.61

3.99

Cdh Tj = +7 °C

0.983

0.985

Pdh Tj = 12°C

3 kW

2.7 kW

COP Tj = 12°C

6.19

5.58

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

6 kW

6 kW

COP Tj = Tbiv

2.74

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6 kW

6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.995

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2646 kWh

3779 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80VAA + ERST17D-*M*D
Configure model
Model name
PUZ-SWM80VAA + ERST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.12

5.74

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.993

0.991

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.989

0.986

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.98

0.976

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.972

0.971

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1034 kWh

836 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

130 %

Prated

8 kW

8 kW

SCOP

4.66

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.993

0.995

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.984

0.989

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.996

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3543 kWh

4961 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80YAA + ERST17D-*M*D
Configure model
Model name
PUZ-SWM80YAA + ERST17D-*M*D
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.06

5.62

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.984

0.979

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.97

0.965

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.959

0.958

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Annual energy consumption Qce

1051 kWh

853 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

130 %

Prated

8 kW

8 kW

SCOP

4.65

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.99

0.993

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.976

0.984

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.975

0.979

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.955

0.955

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.995

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3555 kWh

4972 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM60VAA + ERST17D-*M*BD
Configure model
Model name
PUZ-SWM60VAA + ERST17D-*M*BD
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5 kW

4 kW

El input

1 kW

1.63 kW

COP

5

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.5 kW

1.14 kW

Cooling capacity

5.1

6

EER

3.4

5.25

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.1 kW

6 kW

SEER

3.88

5.91

Pdc Tj = 35°C

5.1 kW

6 kW

EER Tj = 35°C

3.4

5.25

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

3.76 kW

4.42 kW

EER Tj = 30°C

3.84

5.95

Cdc Tj = 30 °C

0.985

0.98

Pdc Tj = 25°C

2.42 kW

3.3 kW

EER Tj = 25°C

4.07

6.38

Cdc Tj = 25 °C

0.975

0.971

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.57

7

Cdc Tj = 20 °C

0.973

0.97

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

789 kWh

609 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

128 %

Prated

6 kW

6 kW

SCOP

4.68

3.28

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.31 kW

COP Tj = -7°C

3.38

2.27

Cdh Tj = -7 °C

0.991

0.994

Pdh Tj = +2°C

4.79 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

4.9 kW

4.1 kW

COP Tj = +7°C

5.61

3.99

Cdh Tj = +7 °C

0.983

0.985

Pdh Tj = 12°C

3 kW

2.7 kW

COP Tj = 12°C

6.19

5.58

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

6 kW

6 kW

COP Tj = Tbiv

2.74

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6 kW

6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.995

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2646 kWh

3779 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80VAA + ERST17D-*M*BD
Configure model
Model name
PUZ-SWM80VAA + ERST17D-*M*BD
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.12

5.74

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.993

0.991

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.989

0.986

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.98

0.976

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.972

0.971

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1034 kWh

836 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

130 %

Prated

8 kW

8 kW

SCOP

4.66

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.993

0.995

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.984

0.989

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.996

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3543 kWh

4961 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80YAA + ERST17D-*M*BD
Configure model
Model name
PUZ-SWM80YAA + ERST17D-*M*BD
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.06

5.62

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.984

0.979

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.97

0.965

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.959

0.958

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Annual energy consumption Qce

1051 kWh

853 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

130 %

Prated

8 kW

8 kW

SCOP

4.65

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.99

0.993

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.976

0.984

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.975

0.979

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.955

0.955

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.995

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3555 kWh

4972 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

134 %

COP

3.2

Heating up time

1:27 h:min

Standby power input

39 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM60VAA + ERST17D-*M*BE
Configure model
Model name
PUZ-SWM60VAA + ERST17D-*M*BE
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5 kW

4 kW

El input

1 kW

1.63 kW

COP

5

2.45

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.5 kW

1.14 kW

Cooling capacity

5.1

6

EER

3.4

5.25

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

5.1 kW

6 kW

SEER

3.88

5.91

Pdc Tj = 35°C

5.1 kW

6 kW

EER Tj = 35°C

3.4

5.25

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

3.76 kW

4.42 kW

EER Tj = 30°C

3.84

5.95

Cdc Tj = 30 °C

0.985

0.98

Pdc Tj = 25°C

2.42 kW

3.3 kW

EER Tj = 25°C

4.07

6.38

Cdc Tj = 25 °C

0.975

0.971

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.57

7

Cdc Tj = 20 °C

0.973

0.97

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

789 kWh

609 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

128 %

Prated

6 kW

6 kW

SCOP

4.68

3.28

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.37 kW

5.31 kW

COP Tj = -7°C

3.38

2.27

Cdh Tj = -7 °C

0.991

0.994

Pdh Tj = +2°C

4.79 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.985

0.989

Pdh Tj = +7°C

4.9 kW

4.1 kW

COP Tj = +7°C

5.61

3.99

Cdh Tj = +7 °C

0.983

0.985

Pdh Tj = 12°C

3 kW

2.7 kW

COP Tj = 12°C

6.19

5.58

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

6 kW

6 kW

COP Tj = Tbiv

2.74

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6 kW

6 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.74

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.993

0.995

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

2646 kWh

3779 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126 %

COP

3.01

Heating up time

1:45 h:min

Standby power input

36.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80VAA + ERST17D-*M*BE
Configure model
Model name
PUZ-SWM80VAA + ERST17D-*M*BE
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.12

5.74

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.993

0.991

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.989

0.986

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.98

0.976

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.972

0.971

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

1034 kWh

836 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

184 %

130 %

Prated

8 kW

8 kW

SCOP

4.66

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.993

0.995

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.984

0.989

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.983

0.986

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.969

0.969

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.996

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3543 kWh

4961 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126 %

COP

3.01

Heating up time

1:45 h:min

Standby power input

36.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l

PUZ-SWM80YAA + ERST17D-*M*BE
Configure model
Model name
PUZ-SWM80YAA + ERST17D-*M*BE
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6 kW

4 kW

El input

1.2 kW

1.6 kW

COP

5

2.5

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.22 kW

1.63 kW

Cooling capacity

7.1

8

EER

3.2

4.9

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.1 kW

8 kW

SEER

4.06

5.62

Pdc Tj = 35°C

7.1 kW

8 kW

EER Tj = 35°C

3.2

4.9

Cdc Tj = 35 °C

0.99

0.987

Pdc Tj = 30°C

5.23 kW

5.92 kW

EER Tj = 30°C

3.85

5.7

Cdc Tj = 30 °C

0.984

0.979

Pdc Tj = 25°C

3.36 kW

3.79 kW

EER Tj = 25°C

4.55

6

Cdc Tj = 25 °C

0.97

0.965

Pdc Tj = 20°C

2.5 kW

3.5 kW

EER Tj = 20°C

4.69

6.75

Cdc Tj = 20 °C

0.959

0.958

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Annual energy consumption Qce

1051 kWh

853 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

130 %

Prated

8 kW

8 kW

SCOP

4.65

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

3.2

2.27

Cdh Tj = -7 °C

0.99

0.993

Pdh Tj = +2°C

4.4 kW

4.4 kW

COP Tj = +2°C

4.75

3.19

Cdh Tj = +2 °C

0.976

0.984

Pdh Tj = +7°C

5 kW

4.4 kW

COP Tj = +7°C

5.61

4.18

Cdh Tj = +7 °C

0.975

0.979

Pdh Tj = 12°C

3 kW

2.8 kW

COP Tj = 12°C

6.19

5.79

Cdh Tj = +12 °C

0.955

0.955

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

3.2

2.27

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.5 kW

7.4 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.995

WTOL

60 °C

60 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.5 kW

0.6 kW

Annual energy consumption Qhe

3555 kWh

4972 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

126 %

COP

3.01

Heating up time

1:45 h:min

Standby power input

36.4 W

Reference hot water temperature

53 °C

Mixed water at 40°C

236 l