1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
126 %
Prated
6 kW
6 kW
SCOP
4.59
3.23
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2701 kWh
3834 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
129 %
Prated
8 kW
8 kW
SCOP
4.59
3.3
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3599 kWh
5016 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
128 %
Prated
8 kW
8 kW
SCOP
4.55
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3636 kWh
5053 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
6 kW
6 kW
SCOP
4.68
3.28
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2646 kWh
3779 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.66
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3543 kWh
4961 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
130 %
Prated
8 kW
8 kW
SCOP
4.65
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3555 kWh
4972 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
6 kW
6 kW
SCOP
4.68
3.28
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2646 kWh
3779 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.66
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3543 kWh
4961 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
130 %
Prated
8 kW
8 kW
SCOP
4.65
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3555 kWh
4972 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
134 %
COP
3.2
Heating up time
1:27 h:min
Standby power input
39 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5 kW
4 kW
El input
1 kW
1.63 kW
COP
5
2.45
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.5 kW
1.14 kW
Cooling capacity
5.1
6
EER
3.4
5.25
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
5.1 kW
6 kW
SEER
3.88
5.91
Pdc Tj = 35°C
5.1 kW
6 kW
EER Tj = 35°C
3.4
5.25
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
3.76 kW
4.42 kW
EER Tj = 30°C
3.84
5.95
Cdc Tj = 30 °C
0.985
0.98
Pdc Tj = 25°C
2.42 kW
3.3 kW
EER Tj = 25°C
4.07
6.38
Cdc Tj = 25 °C
0.975
0.971
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.57
7
Cdc Tj = 20 °C
0.973
0.97
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
789 kWh
609 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
6 kW
6 kW
SCOP
4.68
3.28
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.37 kW
5.31 kW
COP Tj = -7°C
3.38
2.27
Cdh Tj = -7 °C
0.991
0.994
Pdh Tj = +2°C
4.79 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.985
0.989
Pdh Tj = +7°C
4.9 kW
4.1 kW
COP Tj = +7°C
5.61
3.99
Cdh Tj = +7 °C
0.983
0.985
Pdh Tj = 12°C
3 kW
2.7 kW
COP Tj = 12°C
6.19
5.58
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
6 kW
6 kW
COP Tj = Tbiv
2.74
1.98
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6 kW
6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.98
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.993
0.995
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
2646 kWh
3779 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
126 %
COP
3.01
Heating up time
1:45 h:min
Standby power input
36.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.12
5.74
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.993
0.991
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.989
0.986
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.98
0.976
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.972
0.971
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Annual energy consumption Qce
1034 kWh
836 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
130 %
Prated
8 kW
8 kW
SCOP
4.66
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.993
0.995
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.984
0.989
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.983
0.986
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.969
0.969
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3543 kWh
4961 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
126 %
COP
3.01
Heating up time
1:45 h:min
Standby power input
36.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6 kW
4 kW
El input
1.2 kW
1.6 kW
COP
5
2.5
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
2.22 kW
1.63 kW
Cooling capacity
7.1
8
EER
3.2
4.9
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
7.1 kW
8 kW
SEER
4.06
5.62
Pdc Tj = 35°C
7.1 kW
8 kW
EER Tj = 35°C
3.2
4.9
Cdc Tj = 35 °C
0.99
0.987
Pdc Tj = 30°C
5.23 kW
5.92 kW
EER Tj = 30°C
3.85
5.7
Cdc Tj = 30 °C
0.984
0.979
Pdc Tj = 25°C
3.36 kW
3.79 kW
EER Tj = 25°C
4.55
6
Cdc Tj = 25 °C
0.97
0.965
Pdc Tj = 20°C
2.5 kW
3.5 kW
EER Tj = 20°C
4.69
6.75
Cdc Tj = 20 °C
0.959
0.958
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Annual energy consumption Qce
1051 kWh
853 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
54 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
130 %
Prated
8 kW
8 kW
SCOP
4.65
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.08 kW
7.08 kW
COP Tj = -7°C
3.2
2.27
Cdh Tj = -7 °C
0.99
0.993
Pdh Tj = +2°C
4.4 kW
4.4 kW
COP Tj = +2°C
4.75
3.19
Cdh Tj = +2 °C
0.976
0.984
Pdh Tj = +7°C
5 kW
4.4 kW
COP Tj = +7°C
5.61
4.18
Cdh Tj = +7 °C
0.975
0.979
Pdh Tj = 12°C
3 kW
2.8 kW
COP Tj = 12°C
6.19
5.79
Cdh Tj = +12 °C
0.955
0.955
Pdh Tj = Tbiv
7.08 kW
7.08 kW
COP Tj = Tbiv
3.2
2.27
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.5 kW
7.4 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.63
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.995
WTOL
60 °C
60 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.5 kW
0.6 kW
Annual energy consumption Qhe
3555 kWh
4972 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
126 %
COP
3.01
Heating up time
1:45 h:min
Standby power input
36.4 W
Reference hot water temperature
53 °C
Mixed water at 40°C
236 l