Certificate holders

Subtype

Air Source Heat Pump R290-08

Certificate Holder
Jiangsu Sunrain Solar Energy Co., Ltd.
Ninghai Industrial Zone, 222243 Lianyungang City, Jiangsu Province

China
Registration number
041-K085-02
Certification Body
BRE Global Limited
Subtype title
Air Source Heat Pump R290-08
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,050 kg

Certification Date
01.02.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

SMHP-008C1
Configure model
Model name
SMHP-008C1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.23 kW

8.12 kW

El input

1.65 kW

2.60 kW

COP

5.00

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

146 %

Prated

8.21 kW

8.35 kW

SCOP

4.93

3.72

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.27 kW

7.39 kW

COP Tj = -7°C

3.40

2.35

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.46 kW

4.51 kW

COP Tj = +2°C

4.86

3.69

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.64 kW

3.56 kW

COP Tj = +7°C

6.39

4.87

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.26 kW

4.09 kW

COP Tj = 12°C

8.01

6.83

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.27 kW

7.39 kW

COP Tj = Tbiv

3.40

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.06 kW

8.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.92

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

38 W

38 W

PSB

13 W

13 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.26 kW

Annual energy consumption Qhe

3445 kWh

4634 kWh

SMHP-008C3
Configure model
Model name
SMHP-008C3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.99 kW

8.12 kW

El input

1.63 kW

2.60 kW

COP

4.91

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

8.20 kW

8.04 kW

SCOP

4.84

3.60

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.25 kW

7.11 kW

COP Tj = -7°C

3.31

2.33

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.45 kW

4.34 kW

COP Tj = +2°C

4.81

3.59

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.48 kW

3.43 kW

COP Tj = +7°C

6.11

4.63

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.08 kW

3.95 kW

COP Tj = 12°C

8.06

6.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.25 kW

7.11 kW

COP Tj = Tbiv

3.31

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.04 kW

7.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.92

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

13 W

13 W

PTO

38 W

38 W

PSB

13 W

13 W

PCK

83 W

83 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.15 kW

0.24 kW

Annual energy consumption Qhe

3497 kWh

4615 kWh