Certificate holders

Subtype

BAXI AURIGA HP+ 30

Certificate Holder
BAXI S.p.A.
Via Trozzetti, 20
Bassano del Grappa (VI)
Italy
Registration number
007-DO0174
Certification Body
Kiwa Nederland B.V.
Subtype title
BAXI AURIGA HP+ 30
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,750 kg

Certification Date
21.02.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v12)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AURIGA HP+ 30T
Configure model
Model name
AURIGA HP+ 30T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30.00 kW

30.00 kW

El input

6.52 kW

10.07 kW

COP

4.60

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.56 kW

6.98 kW

Cooling capacity

23.30

30.00

EER

3.08

4.30

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

23.30 kW

30.00 kW

SEER

4.55

5.31

Pdc Tj = 35°C

23.30 kW

30.00 kW

EER Tj = 35°C

3.08

4.30

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

17.68 kW

22.11 kW

EER Tj = 30°C

4.15

5.17

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.37 kW

14.21 kW

EER Tj = 25°C

5.62

6.63

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.78 kW

7.90 kW

EER Tj = 20°C

5.80

7.20

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

300 W

PTO

166 W

166 W

PSB

0 W

0 W

PCK

0 W

0 W

Annual energy consumption Qce

3075 kWh

3390 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

30.00 kW

30.00 kW

SCOP

5.17

3.96

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

26.41 kW

26.54 kW

COP Tj = -7°C

2.97

2.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

16.15 kW

16.25 kW

COP Tj = +2°C

5.21

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.38 kW

10.39 kW

COP Tj = +7°C

7.15

5.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.17 kW

8.30 kW

COP Tj = 12°C

8.01

7.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

26.41 kW

26.54 kW

COP Tj = Tbiv

2.97

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.31 kW

24.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

135 W

135 W

PTO

200 W

175 W

PSB

135 W

135 W

PCK

90 W

90 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.69 kW

4.93 kW

Annual energy consumption Qhe

3390 kWh

3149 kWh

AURIGA HP+/TX 30T
Configure model
Model name
AURIGA HP+/TX 30T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30.00 kW

30.00 kW

El input

6.52 kW

10.07 kW

COP

4.60

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.56 kW

6.98 kW

Cooling capacity

23.30

30.00

EER

3.08

4.30

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

23.30 kW

30.00 kW

SEER

4.55

5.31

Pdc Tj = 35°C

23.30 kW

30.00 kW

EER Tj = 35°C

3.08

4.30

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

17.68 kW

22.11 kW

EER Tj = 30°C

4.15

5.17

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.37 kW

14.21 kW

EER Tj = 25°C

5.62

6.63

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.78 kW

7.90 kW

EER Tj = 20°C

5.80

7.20

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

300 W

PTO

166 W

166 W

PSB

0 W

0 W

PCK

0 W

0 W

Annual energy consumption Qce

3075 kWh

3390 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

30.00 kW

30.00 kW

SCOP

5.17

3.96

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

26.41 kW

26.54 kW

COP Tj = -7°C

2.97

2.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

16.15 kW

16.25 kW

COP Tj = +2°C

5.21

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.38 kW

10.39 kW

COP Tj = +7°C

7.15

5.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.17 kW

8.30 kW

COP Tj = 12°C

8.01

7.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

26.41 kW

26.54 kW

COP Tj = Tbiv

2.97

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.31 kW

25.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

135 W

135 W

PTO

200 W

175 W

PSB

135 W

135 W

PCK

90 W

90 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.69 kW

4.93 kW

Annual energy consumption Qhe

3390 kWh

3149 kWh