Certificate holders

Subtype

Intelligent Inverter Heat Pump R290- U15+U20

Certificate Holder
Guangdong PHNIX Eco-Energy Solution Ltd.
No. 3 Tianyuan Road Dagang Town
511470 Guangdong
China
Registration number
041-K020-14
Certification Body
BRE
Subtype title
Intelligent Inverter Heat Pump R290- U15+U20
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,750 kg

Certification Date
15.03.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 13
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

U15
Configure model
Model name
U15
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.42 kW

El input

0.82 kW

1.53 kW

COP

4.90

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

141 %

Prated

4.48 kW

4.75 kW

SCOP

4.96

3.59

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

3.96 kW

4.20 kW

COP Tj = -7°C

3.14

2.22

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.63 kW

2.63 kW

COP Tj = +2°C

4.91

3.52

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.96 kW

1.79 kW

COP Tj = +7°C

6.63

4.77

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.33 kW

2.04 kW

COP Tj = 12°C

8.81

6.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.96 kW

4.20 kW

COP Tj = Tbiv

3.14

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.24 kW

4.48 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.81

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

11 W

11 W

PSB

10 W

10 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.23 kW

0.28 kW

Annual energy consumption Qhe

1864 kWh

2735 kWh

U20
Configure model
Model name
U20
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.10 kW

5.47 kW

El input

1.26 kW

1.84 kW

COP

4.83

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

135 %

Prated

5.63 kW

5.58 kW

SCOP

4.87

3.46

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

4.98 kW

4.93 kW

COP Tj = -7°C

3.14

2.20

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.06 kW

3.03 kW

COP Tj = +2°C

4.60

3.35

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.07 kW

1.99 kW

COP Tj = +7°C

6.74

4.54

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.49 kW

2.18 kW

COP Tj = 12°C

8.96

6.35

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.98 kW

4.93 kW

COP Tj = Tbiv

3.14

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.49 kW

5.13 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.80

1.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

11 W

11 W

PTO

12 W

12 W

PSB

11 W

11 W

PCK

44 W

44 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.14 kW

0.44 kW

Annual energy consumption Qhe

2387 kWh

3333 kWh