Certificate holders

Subtype

Samsung EHS R290 Mono 12kW & 16kW (space heating/ 260L)

Certificate Holder
Samsung Electronics Air Conditioner Europe B.V.
Evert van de Beekstraat 310
1118 CX Schiphol
Netherlands
Registration number
011-1W0684
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Samsung EHS R290 Mono 12kW & 16kW (space heating/ 260L)
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
26.09.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 12 (as of 2023-03)
Generate PDF Export model CSV
  • Number of models 12

Models

 AE120CXYDGK/EU + MIM-E03EN 
Configure model
Model name
 AE120CXYDGK/EU + MIM-E03EN 
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

 AE160CXYDGK/EU + MIM-E03EN 
Configure model
Model name
 AE160CXYDGK/EU + MIM-E03EN 
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

15.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.70 kW

13.71 kW

COP Tj = -7°C

2.50

1.95

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

8.35 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.40 kW

COP Tj = +7°C

7.10

5.18

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

13.70 kW

COP Tj = Tbiv

2.50

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.20 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

 AE120CXYDEK/EU +AE260CNWMEG/EU 
Configure model
Model name
 AE120CXYDEK/EU +AE260CNWMEG/EU 
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

 AE120CXYDGK/EU + AE260CNWMGG/EU 
Configure model
Model name
 AE120CXYDGK/EU + AE260CNWMGG/EU 
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

 AE160CXYDEK/EU + AE260CNWMEG/EU 
Configure model
Model name
 AE160CXYDEK/EU + AE260CNWMEG/EU 
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

14.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.80 kW

COP Tj = -7°C

2.50

2.00

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

7.81 kW

COP Tj = +2°C

4.52

3.41

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.00 kW

COP Tj = +7°C

7.10

5.13

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

12.80 kW

COP Tj = Tbiv

2.50

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

 AE160CXYDGK/EU + AE260CNWMGG/EU 
Configure model
Model name
 AE160CXYDGK/EU + AE260CNWMGG/EU 
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

15.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

13.71 kW

COP Tj = -7°C

2.50

1.95

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

8.35 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.40 kW

COP Tj = +7°C

7.10

5.18

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

13.70 kW

COP Tj = Tbiv

2.50

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.20 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

AE120CXYBGK/EU
Configure model
Model name
AE120CXYBGK/EU
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

AE160CXYBGK/EU
Configure model
Model name
AE160CXYBGK/EU
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

15.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

13.71 kW

COP Tj = -7°C

2.50

1.95

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

8.35 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.40 kW

COP Tj = +7°C

7.10

5.18

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

13.70 kW

COP Tj = Tbiv

2.50

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.20 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

AE120CXYDEK/EU +AE260RNWMEG/EU
Configure model
Model name
AE120CXYDEK/EU +AE260RNWMEG/EU
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

AE120CXYDGK/EU + AE260RNWMGG/EU
Configure model
Model name
AE120CXYDGK/EU + AE260RNWMGG/EU
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

4.14 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.60 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

AE160CXYDEK/EU + AE260RNWMEG/EU
Configure model
Model name
AE160CXYDEK/EU + AE260RNWMEG/EU
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

14.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.80 kW

COP Tj = -7°C

2.50

2.00

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

7.81 kW

COP Tj = +2°C

4.52

3.41

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.00 kW

COP Tj = +7°C

7.10

5.13

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

12.80 kW

COP Tj = Tbiv

2.50

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l

AE160CXYDGK/EU + AE260RNWMGG/EU
Configure model
Model name
AE160CXYDGK/EU + AE260RNWMGG/EU
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

15.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

13.71 kW

COP Tj = -7°C

2.50

1.95

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

8.35 kW

8.35 kW

COP Tj = +2°C

4.52

3.43

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

5.37 kW

5.40 kW

COP Tj = +7°C

7.10

5.18

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

13.71 kW

13.70 kW

COP Tj = Tbiv

2.50

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

13.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.20 kW

Annual energy consumption Qhe

6793 kWh

8985 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

103 %

COP

2.50

Heating up time

1:20 h:min

Standby power input

85.0 W

Reference hot water temperature

53.1 °C

Mixed water at 40°C

305 l