Certificate holders

Subtype

Alféa Excellia A.I. Tri 14 2024

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700257 / Issue 1
Certification Body
RISE CERT
Subtype title
Alféa Excellia A.I. Tri 14 2024
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
04.03.2024
Testing basis
EN 14511:2022, EN 14825:2022, EN 16147:2017, EN 12102:2022
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Alféa Excellia A.I. Tri 14 2024
Configure model
Model name
Alféa Excellia A.I. Tri 14 2024
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.10 kW

12.00 kW

El input

3.13 kW

4.71 kW

COP

4.18

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

125 %

Prated

13.00 kW

11.00 kW

SCOP

4.00

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

9.70 kW

COP Tj = -7°C

2.50

2.05

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

5.90 kW

COP Tj = +2°C

3.87

3.04

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.40 kW

5.90 kW

COP Tj = +7°C

5.34

4.50

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

7.40 kW

7.10 kW

COP Tj = 12°C

7.25

5.82

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

11.50 kW

9.70 kW

COP Tj = Tbiv

2.50

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.80 kW

Annual energy consumption Qhe

6714 kWh

7096 kWh

Alféa Excellia Duo A.I. Tri 14 2024
Configure model
Model name
Alféa Excellia Duo A.I. Tri 14 2024
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.10 kW

12.00 kW

El input

3.13 kW

4.71 kW

COP

4.18

2.55

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

157 %

125 %

Prated

13.00 kW

11.00 kW

SCOP

4.00

3.20

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

9.70 kW

COP Tj = -7°C

2.50

2.05

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.00 kW

5.90 kW

COP Tj = +2°C

3.87

3.04

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.40 kW

5.90 kW

COP Tj = +7°C

5.34

4.50

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

7.40 kW

7.10 kW

COP Tj = 12°C

7.25

5.82

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

11.50 kW

9.70 kW

COP Tj = Tbiv

2.50

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.20 kW

8.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

24 W

24 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.80 kW

2.80 kW

Annual energy consumption Qhe

6714 kWh

7096 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

100 %

COP

2.50

Heating up time

0:55 h:min

Standby power input

40.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C

250 l