Certificate holders

Subtype

ISILIA S 16 TRI

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700230 / Issue 1
Certification Body
RISE CERT
Subtype title
ISILIA S 16 TRI
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

2,500 kg

Certification Date
13.02.2024
Testing basis
EN 14511:2022, EN 14825:2022, EN 12102:2022
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

ISILIA S 16 TRI
Configure model
Model name
ISILIA S 16 TRI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

13.80 kW

11.20 kW

El input

3.12 kW

4.21 kW

COP

4.42

2.66

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

166 %

130 %

Prated

13.30 kW

13.30 kW

SCOP

4.21

3.32

Tbiv

-7 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

9.50 kW

COP Tj = -7°C

2.73

1.98

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.90 kW

7.20 kW

COP Tj = +2°C

3.96

3.26

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

6.30 kW

6.40 kW

COP Tj = +7°C

5.86

4.78

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

7.20 kW

7.50 kW

COP Tj = 12°C

7.40

6.02

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

11.50 kW

10.50 kW

COP Tj = Tbiv

2.73

2.21

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.30 kW

8.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

60 °C

60 °C

Poff

10 W

10 W

PTO

15 W

15 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

4.90 kW

Annual energy consumption Qhe

6522 kWh

8266 kWh