2,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.20 kW
8.20 kW
El input
2.40 kW
2.93 kW
COP
4.67
2.80
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
130 %
Prated
11.80 kW
11.10 kW
SCOP
4.24
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.40 kW
9.80 kW
COP Tj = -7°C
2.80
2.08
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.30 kW
6.00 kW
COP Tj = +2°C
4.01
3.26
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
6.30 kW
6.30 kW
COP Tj = +7°C
5.81
4.40
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
7.30 kW
7.50 kW
COP Tj = 12°C
7.40
5.70
Cdh Tj = +12 °C
0.980
0.990
Pdh Tj = Tbiv
10.40 kW
9.80 kW
COP Tj = Tbiv
2.80
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.50 kW
8.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.46
1.76
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
15 W
15 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.30 kW
2.70 kW
Annual energy consumption Qhe
5745 kWh
6897 kWh