3,950 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
19.62 kW
19.94 kW
El input
4.32 kW
6.26 kW
COP
4.54
3.18
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
- dB(A)
- dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
143 %
Prated
19.62 kW
19.94 kW
SCOP
4.93
3.78
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
19.62 kW
19.94 kW
COP Tj = +2°C
4.54
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
19.58 kW
19.84 kW
COP Tj = +7°C
4.77
3.50
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
19.53 kW
19.69 kW
COP Tj = 12°C
5.16
4.13
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
19.62 kW
19.94 kW
COP Tj = Tbiv
4.54
3.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.62 kW
19.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.54
3.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5314 kWh
7057 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
- dB(A)
- dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
144 %
Prated
19.62 kW
19.94 kW
SCOP
4.98
3.81
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
19.57 kW
19.81 kW
COP Tj = -7°C
4.86
3.61
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
19.54 kW
19.73 kW
COP Tj = +2°C
5.08
3.95
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
19.52 kW
19.67 kW
COP Tj = +7°C
5.25
4.27
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
19.51 kW
19.62 kW
COP Tj = 12°C
5.30
4.54
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
19.62 kW
19.94 kW
COP Tj = Tbiv
4.54
3.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.62 kW
19.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.54
3.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
9713 kWh
12894 kWh
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
- dB(A)
- dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
142 %
Prated
19.62 kW
19.94 kW
SCOP
4.88
3.75
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
19.61 kW
19.91 kW
COP Tj = -7°C
4.59
3.29
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
19.58 kW
19.79 kW
COP Tj = +2°C
4.83
3.70
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
19.54 kW
19.72 kW
COP Tj = +7°C
5.07
4.01
Cdh Tj = +7 °C
1.00
1.00
Pdh Tj = 12°C
19.51 kW
19.65 kW
COP Tj = 12°C
5.33
4.39
Cdh Tj = +12 °C
1.00
1.00
Pdh Tj = Tbiv
19.62 kW
19.94 kW
COP Tj = Tbiv
4.54
3.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
19.62 kW
19.94 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.54
3.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
65 °C
65 °C
Poff
7 W
7 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
8308 kWh
10986 kWh