Certificate holders

Subtype

DAIKIN ALTHERMA LT MONOBLOC 7KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0080
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA LT MONOBLOC 7KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,450 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

EBLQ07C*V3
Configure model
Model name
EBLQ07C*V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

6.10 kW

El input

1.55 kW

2.22 kW

COP

4.52

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

125 %

Prated

7.00 kW

6.10 kW

SCOP

4.14

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

5.50 kW

COP Tj = -7°C

2.57

1.98

Pdh Tj = +2°C

3.77 kW

3.20 kW

COP Tj = +2°C

4.00

3.17

Pdh Tj = +7°C

2.59 kW

3.60 kW

COP Tj = +7°C

5.75

4.20

Pdh Tj = 12°C

2.61 kW

3.40 kW

COP Tj = 12°C

7.27

5.82

Pdh Tj = Tbiv

6.20 kW

5.50 kW

COP Tj = Tbiv

2.57

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.81 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.15

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

35 °C

55 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.19 kW

3.00 kW

Annual energy consumption Qhe

3460 kWh

3906 kWh

EDLQ07C*V3
Configure model
Model name
EDLQ07C*V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.00 kW

6.10 kW

El input

1.55 kW

2.22 kW

COP

4.52

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

125 %

Prated

7.00 kW

6.10 kW

SCOP

4.14

3.22

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.20 kW

5.50 kW

COP Tj = -7°C

2.57

1.98

Pdh Tj = +2°C

3.77 kW

3.20 kW

COP Tj = +2°C

4.00

3.17

Pdh Tj = +7°C

2.59 kW

3.60 kW

COP Tj = +7°C

5.75

4.20

Pdh Tj = 12°C

2.61 kW

3.40 kW

COP Tj = 12°C

7.27

5.82

Pdh Tj = Tbiv

6.20 kW

5.50 kW

COP Tj = Tbiv

2.57

1.98

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.81 kW

3.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.15

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

35 °C

55 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.19 kW

3.00 kW

Annual energy consumption Qhe

3460 kWh

3906 kWh