Certificate holders

Subtype

DAIKIN ALTHERMA LT MONOBLOC 5 KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0079
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA LT MONOBLOC 5 KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,300 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

EDLQ05C*V3
Configure model
Model name
EDLQ05C*V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.40 kW

4.20 kW

El input

0.88 kW

1.56 kW

COP

5.00

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

125 %

Prated

4.40 kW

4.20 kW

SCOP

4.39

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.01 kW

3.60 kW

COP Tj = -7°C

2.90

1.98

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.40 kW

2.34 kW

COP Tj = +2°C

4.21

3.10

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.70 kW

2.80 kW

COP Tj = +7°C

5.85

4.27

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

2.04 kW

2.70 kW

COP Tj = 12°C

7.71

6.33

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.36 kW

4.20 kW

COP Tj = Tbiv

2.52

1.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

35 °C

55 °C

Poff

8 W

8 W

PTO

6 W

6 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2679 kWh

EBLQ05C*V3
Configure model
Model name
EBLQ05C*V3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.40 kW

4.20 kW

El input

0.88 kW

1.56 kW

COP

5.00

2.70

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

172 %

125 %

Prated

4.40 kW

4.20 kW

SCOP

4.39

3.20

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.01 kW

3.60 kW

COP Tj = -7°C

2.90

1.98

Cdh Tj = -7 °C

 

 

Pdh Tj = +2°C

2.40 kW

2.34 kW

COP Tj = +2°C

4.21

3.10

Cdh Tj = +2 °C

 

 

Pdh Tj = +7°C

1.70 kW

2.80 kW

COP Tj = +7°C

5.85

4.27

Cdh Tj = +7 °C

 

 

Pdh Tj = 12°C

2.04 kW

2.70 kW

COP Tj = 12°C

7.71

6.33

Cdh Tj = +12 °C

 

 

Pdh Tj = Tbiv

4.36 kW

4.20 kW

COP Tj = Tbiv

2.52

1.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.36 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.65

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

35 °C

55 °C

Poff

8 W

8 W

PTO

6 W

6 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2040 kWh

2679 kWh