1,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.13 kW
2.73 kW
El input
0.64 kW
1.05 kW
COP
4.89
2.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
156 %
Prated
3.76 kW
3.31 kW
SCOP
6.41
3.98
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.31 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.31 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
783 kWh
1111 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
155 %
107 %
Prated
3.91 kW
2.82 kW
SCOP
3.96
2.76
Tbiv
-13 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.36 kW
1.78 kW
COP Tj = -7°C
3.44
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.96 kW
1.70 kW
COP Tj = +2°C
4.80
3.54
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.34 kW
2.09 kW
COP Tj = +7°C
6.54
4.79
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.43 kW
COP Tj = 12°C
8.00
6.07
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
2.99 kW
2.30 kW
COP Tj = Tbiv
2.80
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.91 kW
2.82 kW
Annual energy consumption Qhe
2439 kWh
2517 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.22
2.30
COP Tj = -15°C (if TOL<-20°C)
2.17
1.72
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
130 %
Prated
4.00 kW
3.51 kW
SCOP
4.70
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.10 kW
COP Tj = -7°C
3.19
2.08
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.18 kW
2.04 kW
COP Tj = +2°C
4.50
3.26
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.32 kW
2.02 kW
COP Tj = +7°C
6.15
4.36
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.74 kW
2.44 kW
COP Tj = 12°C
8.42
5.86
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
3.54 kW
3.10 kW
COP Tj = Tbiv
3.19
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.24 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
0.76 kW
Annual energy consumption Qhe
1758 kWh
2177 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.13 kW
2.73 kW
El input
0.64 kW
1.05 kW
COP
4.89
2.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
156 %
Prated
3.76 kW
3.31 kW
SCOP
6.41
3.98
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.31 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.31 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
783 kWh
1111 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
155 %
107 %
Prated
3.91 kW
2.82 kW
SCOP
3.96
2.76
Tbiv
-13 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.36 kW
1.78 kW
COP Tj = -7°C
3.44
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.96 kW
1.70 kW
COP Tj = +2°C
4.80
3.54
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.34 kW
2.09 kW
COP Tj = +7°C
6.54
4.79
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.43 kW
COP Tj = 12°C
8.00
6.07
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
2.99 kW
2.30 kW
COP Tj = Tbiv
2.80
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.91 kW
2.82 kW
Annual energy consumption Qhe
2439 kWh
2517 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.22
2.30
COP Tj = -15°C (if TOL<-20°C)
2.17
1.72
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
130 %
Prated
4.00 kW
3.51 kW
SCOP
4.70
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.10 kW
COP Tj = -7°C
3.19
2.08
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.18 kW
2.04 kW
COP Tj = +2°C
4.50
3.26
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.32 kW
2.02 kW
COP Tj = +7°C
6.15
4.36
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.74 kW
2.44 kW
COP Tj = 12°C
8.42
5.86
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
3.54 kW
3.10 kW
COP Tj = Tbiv
3.19
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.24 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
0.76 kW
Annual energy consumption Qhe
1758 kWh
2177 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.88
Heating up time
02:06 h:min
Standby power input
80.0 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
242 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
03:00 h:min
Standby power input
80.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
246 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
102 %
COP
2.45
Heating up time
02:32 h:min
Standby power input
80.0 W
Reference hot water temperature
50.7 °C
Mixed water at 40°C
246 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.13 kW
2.73 kW
El input
0.64 kW
1.05 kW
COP
4.89
2.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
150 %
Prated
3.76 kW
3.31 kW
SCOP
6.04
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.31 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.31 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
831 kWh
1159 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
106 %
Prated
3.91 kW
2.82 kW
SCOP
3.92
2.73
Tbiv
-13 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.36 kW
1.78 kW
COP Tj = -7°C
3.44
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.96 kW
1.70 kW
COP Tj = +2°C
4.80
3.54
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.34 kW
2.09 kW
COP Tj = +7°C
6.54
4.79
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.43 kW
COP Tj = 12°C
8.00
6.07
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
2.99 kW
2.30 kW
COP Tj = Tbiv
2.80
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.91 kW
2.82 kW
Annual energy consumption Qhe
2463 kWh
2541 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.22
2.30
COP Tj = -15°C (if TOL<-20°C)
2.17
1.72
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
4.00 kW
3.51 kW
SCOP
4.60
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.10 kW
COP Tj = -7°C
3.19
2.08
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.18 kW
2.04 kW
COP Tj = +2°C
4.50
3.26
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.32 kW
2.02 kW
COP Tj = +7°C
6.15
4.36
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.74 kW
2.44 kW
COP Tj = 12°C
8.42
5.86
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
3.54 kW
3.10 kW
COP Tj = Tbiv
3.19
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.24 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
0.76 kW
Annual energy consumption Qhe
1798 kWh
2217 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.13 kW
2.73 kW
El input
0.64 kW
1.05 kW
COP
4.89
2.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
150 %
Prated
3.76 kW
3.31 kW
SCOP
6.04
3.81
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.31 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.31 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
831 kWh
1159 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
106 %
Prated
3.91 kW
2.82 kW
SCOP
3.92
2.73
Tbiv
-13 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.36 kW
1.78 kW
COP Tj = -7°C
3.44
2.32
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.96 kW
1.70 kW
COP Tj = +2°C
4.80
3.54
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.34 kW
2.09 kW
COP Tj = +7°C
6.54
4.79
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.43 kW
COP Tj = 12°C
8.00
6.07
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
2.99 kW
2.30 kW
COP Tj = Tbiv
2.80
1.72
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.91 kW
2.82 kW
Annual energy consumption Qhe
2463 kWh
2541 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.22
2.30
COP Tj = -15°C (if TOL<-20°C)
2.17
1.72
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
44 dB(A)
44 dB(A)
Sound power level outdoor
51 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
4.00 kW
3.51 kW
SCOP
4.60
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.10 kW
COP Tj = -7°C
3.19
2.08
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
2.18 kW
2.04 kW
COP Tj = +2°C
4.50
3.26
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.32 kW
2.02 kW
COP Tj = +7°C
6.15
4.36
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.74 kW
2.44 kW
COP Tj = 12°C
8.42
5.86
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
3.54 kW
3.10 kW
COP Tj = Tbiv
3.19
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.24 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.86
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
0.76 kW
Annual energy consumption Qhe
1798 kWh
2217 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.88
Heating up time
02:06 h:min
Standby power input
80.0 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
242 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
03:00 h:min
Standby power input
80.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
246 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
1.02 %
COP
2.45
Heating up time
02:32 h:min
Standby power input
80.0 W
Reference hot water temperature
50.7 °C
Mixed water at 40°C
246 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.42 kW
3.69 kW
El input
0.95 kW
1.38 kW
COP
4.68
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
156 %
Prated
3.76 kW
3.30 kW
SCOP
6.41
3.98
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.30 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.30 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
783 kWh
1108 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
110 %
Prated
5.19 kW
4.00 kW
SCOP
4.02
2.83
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.96 kW
2.44 kW
COP Tj = -7°C
3.41
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.97 kW
1.72 kW
COP Tj = +2°C
4.87
3.56
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.36 kW
2.11 kW
COP Tj = +7°C
6.57
4.89
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.52 kW
COP Tj = 12°C
8.00
6.71
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.24 kW
3.26 kW
COP Tj = Tbiv
2.42
1.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.19 kW
4.00 kW
Annual energy consumption Qhe
3182 kWh
3485 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.30
3.26
COP Tj = -15°C (if TOL<-20°C)
2.11
1.68
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
135 %
Prated
5.22 kW
5.24 kW
SCOP
4.44
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.83 kW
4.33 kW
COP Tj = -7°C
2.71
2.00
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.57 kW
COP Tj = +2°C
4.26
3.36
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.30 kW
2.09 kW
COP Tj = +7°C
6.06
4.67
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.71 kW
2.52 kW
COP Tj = 12°C
8.39
6.41
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.61 kW
4.63 kW
COP Tj = Tbiv
2.64
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.90 kW
3.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.32 kW
1.54 kW
Annual energy consumption Qhe
2427 kWh
3129 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.88
Heating up time
02:06 h:min
Standby power input
80.0 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
242 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
03:00 h:min
Standby power input
80.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
246 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
1.02 %
COP
2.45
Heating up time
02:32 h:min
Standby power input
80.0 W
Reference hot water temperature
50.7 °C
Mixed water at 40°C
246 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.42 kW
3.69 kW
El input
0.95 kW
1.38 kW
COP
4.68
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
253 %
156 %
Prated
3.76 kW
3.30 kW
SCOP
6.41
3.98
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.76 kW
3.30 kW
COP Tj = +2°C
3.69
2.24
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.25 kW
2.06 kW
COP Tj = +7°C
5.81
3.36
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.70 kW
2.41 kW
COP Tj = 12°C
8.08
5.31
Cdh Tj = +12 °C
0.97
0.98
Pdh Tj = Tbiv
3.76 kW
3.30 kW
COP Tj = Tbiv
3.69
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.76 kW
3.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.69
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
783 kWh
1108 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
110 %
Prated
5.19 kW
4.00 kW
SCOP
4.02
2.83
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.96 kW
2.44 kW
COP Tj = -7°C
3.41
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.97 kW
1.72 kW
COP Tj = +2°C
4.87
3.56
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.36 kW
2.11 kW
COP Tj = +7°C
6.57
4.89
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.52 kW
COP Tj = 12°C
8.00
6.71
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.24 kW
3.26 kW
COP Tj = Tbiv
2.42
1.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.19 kW
4.00 kW
Annual energy consumption Qhe
3182 kWh
3485 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.30
3.26
COP Tj = -15°C (if TOL<-20°C)
2.11
1.68
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
135 %
Prated
5.22 kW
5.24 kW
SCOP
4.44
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.83 kW
4.33 kW
COP Tj = -7°C
2.71
2.00
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.57 kW
COP Tj = +2°C
4.26
3.36
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.30 kW
2.09 kW
COP Tj = +7°C
6.06
4.67
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.71 kW
2.52 kW
COP Tj = 12°C
8.39
6.41
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.61 kW
4.63 kW
COP Tj = Tbiv
2.64
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.90 kW
3.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.32 kW
1.54 kW
Annual energy consumption Qhe
2427 kWh
3129 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.42 kW
3.69 kW
El input
0.95 kW
1.38 kW
COP
4.68
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
238 %
Prated
3.30 kW
3.76 kW
SCOP
3.81
6.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.30 kW
3.76 kW
COP Tj = +2°C
2.24
3.69
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.06 kW
2.25 kW
COP Tj = +7°C
3.36
5.81
Cdh Tj = +7 °C
0.98
0.97
Pdh Tj = 12°C
2.41 kW
2.70 kW
COP Tj = 12°C
5.31
8.08
Cdh Tj = +12 °C
0.98
0.97
Pdh Tj = Tbiv
3.30 kW
3.76 kW
COP Tj = Tbiv
2.24
3.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.76 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
3.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1156 kWh
831 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
109 %
Prated
5.19 kW
4.00 kW
SCOP
3.99
2.81
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.96 kW
2.44 kW
COP Tj = -7°C
3.41
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.97 kW
1.72 kW
COP Tj = +2°C
4.87
3.56
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.36 kW
2.11 kW
COP Tj = +7°C
6.57
4.89
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.52 kW
COP Tj = 12°C
8.00
6.71
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.24 kW
3.26 kW
COP Tj = Tbiv
2.42
1.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.19 kW
4.00 kW
Annual energy consumption Qhe
3206 kWh
3509 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.30
3.26
COP Tj = -15°C (if TOL<-20°C)
2.11
1.68
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
172 %
134 %
Prated
5.22 kW
5.24 kW
SCOP
4.37
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.83 kW
4.33 kW
COP Tj = -7°C
2.71
2.00
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.57 kW
COP Tj = +2°C
4.26
3.36
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.30 kW
2.09 kW
COP Tj = +7°C
6.06
4.67
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.71 kW
2.52 kW
COP Tj = 12°C
8.39
6.41
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.61 kW
4.63 kW
COP Tj = Tbiv
2.64
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.90 kW
3.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.32 kW
1.54 kW
Annual energy consumption Qhe
2467 kWh
3169 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
2.88
Heating up time
02:06 h:min
Standby power input
80.0 W
Reference hot water temperature
50.5 °C
Mixed water at 40°C
242 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
106 %
COP
2.55
Heating up time
03:00 h:min
Standby power input
80.0 W
Reference hot water temperature
46.9 °C
Mixed water at 40°C
246 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
1.02 %
COP
2.45
Heating up time
02:32 h:min
Standby power input
80.0 W
Reference hot water temperature
50.7 °C
Mixed water at 40°C
246 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.42 kW
3.69 kW
El input
0.95 kW
1.38 kW
COP
4.68
2.67
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
238 %
Prated
3.30 kW
3.76 kW
SCOP
3.81
6.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.30 kW
3.76 kW
COP Tj = +2°C
2.24
3.69
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.06 kW
2.25 kW
COP Tj = +7°C
3.36
5.81
Cdh Tj = +7 °C
0.98
0.97
Pdh Tj = 12°C
2.41 kW
2.70 kW
COP Tj = 12°C
5.31
8.08
Cdh Tj = +12 °C
0.98
0.97
Pdh Tj = Tbiv
3.30 kW
3.76 kW
COP Tj = Tbiv
2.24
3.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.76 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.24
3.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1156 kWh
831 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
109 %
Prated
5.19 kW
4.00 kW
SCOP
3.99
2.81
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.96 kW
2.44 kW
COP Tj = -7°C
3.41
2.42
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
1.97 kW
1.72 kW
COP Tj = +2°C
4.87
3.56
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.36 kW
2.11 kW
COP Tj = +7°C
6.57
4.89
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.68 kW
2.52 kW
COP Tj = 12°C
8.00
6.71
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.24 kW
3.26 kW
COP Tj = Tbiv
2.42
1.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.30 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.11
1.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.19 kW
4.00 kW
Annual energy consumption Qhe
3206 kWh
3509 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.30
3.26
COP Tj = -15°C (if TOL<-20°C)
2.11
1.68
Cdh Tj = -15 °C
0.990
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
53 dB(A)
54 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
172 %
134 %
Prated
5.22 kW
5.24 kW
SCOP
4.37
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.83 kW
4.33 kW
COP Tj = -7°C
2.71
2.00
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
2.67 kW
2.57 kW
COP Tj = +2°C
4.26
3.36
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.30 kW
2.09 kW
COP Tj = +7°C
6.06
4.67
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
2.71 kW
2.52 kW
COP Tj = 12°C
8.39
6.41
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
4.61 kW
4.63 kW
COP Tj = Tbiv
2.64
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.90 kW
3.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
11 W
11 W
PTO
11 W
11 W
PSB
11 W
11 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.32 kW
1.54 kW
Annual energy consumption Qhe
2467 kWh
3169 kWh