0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.37 kW
7.58 kW
El input
1.66 kW
2.65 kW
COP
4.42
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
162 %
Prated
6.87 kW
7.06 kW
SCOP
5.78
4.13
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.87 kW
7.06 kW
COP Tj = +2°C
3.18
2.31
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.38 kW
4.71 kW
COP Tj = +7°C
5.29
3.44
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
3.68 kW
3.56 kW
COP Tj = 12°C
7.37
5.62
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
6.87 kW
7.06 kW
COP Tj = Tbiv
3.18
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.87 kW
7.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.18
2.31
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1586 kWh
2284 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
119 %
Prated
6.03 kW
5.59 kW
SCOP
4.05
3.06
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
3.71 kW
3.77 kW
COP Tj = -7°C
3.42
2.54
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.80 kW
2.59 kW
COP Tj = +2°C
5.04
3.70
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.25 kW
3.12 kW
COP Tj = +7°C
6.63
5.08
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.73 kW
3.67 kW
COP Tj = 12°C
7.71
6.80
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.92 kW
4.56 kW
COP Tj = Tbiv
2.57
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.66 kW
3.29 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.03 kW
5.59 kW
Annual energy consumption Qhe
3665 kWh
4506 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.92
4.56
COP Tj = -15°C (if TOL<-20°C)
2.57
1.92
Cdh Tj = -15 °C
0.980
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
135 %
Prated
7.21 kW
6.39 kW
SCOP
4.75
3.44
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.38 kW
5.66 kW
COP Tj = -7°C
2.93
2.17
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.83 kW
3.49 kW
COP Tj = +2°C
4.73
3.32
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
3.21 kW
3.06 kW
COP Tj = +7°C
6.33
4.67
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.72 kW
3.62 kW
COP Tj = 12°C
7.79
6.23
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.38 kW
5.66 kW
COP Tj = Tbiv
2.93
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.00 kW
5.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.66
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.21 kW
1.30 kW
Annual energy consumption Qhe
3139 kWh
3837 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.12 kW
5.80 kW
El input
1.10 kW
2.00 kW
COP
4.66
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
229 %
162 %
Prated
5.31 kW
5.98 kW
SCOP
5.81
4.12
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.31 kW
5.98 kW
COP Tj = +2°C
3.46
2.33
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
4.12 kW
3.72 kW
COP Tj = +7°C
5.49
3.50
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
3.67 kW
3.52 kW
COP Tj = 12°C
7.40
5.58
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
5.31 kW
5.98 kW
COP Tj = Tbiv
3.46
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.31 kW
5.98 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.46
2.33
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1222 kWh
1938 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
121 %
Prated
5.97 kW
5.51 kW
SCOP
4.13
3.10
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
3.58 kW
3.27 kW
COP Tj = -7°C
3.45
2.55
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.75 kW
2.58 kW
COP Tj = +2°C
5.17
3.80
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.16 kW
3.07 kW
COP Tj = +7°C
6.64
5.07
Cdh Tj = +7 °C
0.940
0.960
Pdh Tj = 12°C
3.69 kW
3.60 kW
COP Tj = 12°C
7.77
6.57
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.87 kW
4.50 kW
COP Tj = Tbiv
2.57
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.10 kW
3.76 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.97 kW
5.51 kW
Annual energy consumption Qhe
3560 kWh
4385 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
136 %
Prated
6.73 kW
6.26 kW
SCOP
4.71
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.96 kW
5.54 kW
COP Tj = -7°C
3.01
2.14
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.67 kW
3.63 kW
COP Tj = +2°C
4.62
3.39
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
3.12 kW
3.01 kW
COP Tj = +7°C
6.36
4.67
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.69 kW
3.57 kW
COP Tj = 12°C
7.82
6.19
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.96 kW
5.54 kW
COP Tj = Tbiv
3.01
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.52 kW
5.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.77
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.21 kW
1.21 kW
Annual energy consumption Qhe
2951 kWh
3731 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.57 kW
4.95 kW
El input
0.95 kW
1.68 kW
COP
4.79
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
237 %
163 %
Prated
6.77 kW
6.60 kW
SCOP
5.99
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.77 kW
6.60 kW
COP Tj = +2°C
3.23
2.23
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
4.52 kW
COP Tj = +7°C
5.52
3.47
Cdh Tj = +7 °C
0.96
0.98
Pdh Tj = 12°C
3.75 kW
3.56 kW
COP Tj = 12°C
7.65
5.68
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
6.77 kW
6.60 kW
COP Tj = Tbiv
3.23
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.77 kW
6.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.23
2.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1510 kWh
2128 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
5.85 kW
5.39 kW
SCOP
4.07
3.03
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
3.51 kW
3.69 kW
COP Tj = -7°C
3.31
2.53
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.73 kW
2.55 kW
COP Tj = +2°C
5.01
3.62
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.19 kW
3.08 kW
COP Tj = +7°C
6.82
5.05
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
3.78 kW
3.64 kW
COP Tj = 12°C
8.52
6.54
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.77 kW
4.40 kW
COP Tj = Tbiv
2.60
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.94 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.85 kW
5.39 kW
Annual energy consumption Qhe
3546 kWh
4380 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.77
4.40
COP Tj = -15°C (if TOL<-20°C)
2.60
1.90
Cdh Tj = -15 °C
0.980
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
134 %
Prated
6.60 kW
6.13 kW
SCOP
4.69
3.43
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.84 kW
5.42 kW
COP Tj = -7°C
2.72
2.13
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.72 kW
3.46 kW
COP Tj = +2°C
4.68
3.36
Cdh Tj = +2 °C
0.960
0.970
Pdh Tj = +7°C
3.18 kW
3.00 kW
COP Tj = +7°C
6.38
4.60
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.74 kW
3.59 kW
COP Tj = 12°C
7.88
6.18
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.27 kW
5.42 kW
COP Tj = Tbiv
2.64
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.27 kW
4.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.64
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.25 kW
Annual energy consumption Qhe
2907 kWh
3688 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.57 kW
4.95 kW
El input
0.95 kW
1.68 kW
COP
4.79
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
231 %
160 %
Prated
6.77 kW
6.60 kW
SCOP
5.85
4.07
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.77 kW
6.60 kW
COP Tj = +2°C
3.23
2.23
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
4.52 kW
COP Tj = +7°C
5.52
3.47
Cdh Tj = +7 °C
0.96
0.98
Pdh Tj = 12°C
3.75 kW
3.56 kW
COP Tj = 12°C
7.65
5.68
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
6.77 kW
6.60 kW
COP Tj = Tbiv
3.23
2.23
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.77 kW
6.60 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.23
2.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1546 kWh
2164 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
159 %
118 %
Prated
5.85 kW
5.39 kW
SCOP
4.05
3.02
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
3.51 kW
3.69 kW
COP Tj = -7°C
3.31
2.53
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
2.73 kW
2.55 kW
COP Tj = +2°C
5.01
3.62
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.19 kW
3.08 kW
COP Tj = +7°C
6.82
5.05
Cdh Tj = +7 °C
0.940
0.950
Pdh Tj = 12°C
3.78 kW
3.64 kW
COP Tj = 12°C
8.52
6.54
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.77 kW
4.40 kW
COP Tj = Tbiv
2.60
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.94 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.53
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.85 kW
5.39 kW
Annual energy consumption Qhe
3565 kWh
4398 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.77
4.40
COP Tj = -15°C (if TOL<-20°C)
2.60
1.90
Cdh Tj = -15 °C
0.980
0.990
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
133 %
Prated
6.60 kW
6.13 kW
SCOP
4.69
3.41
Tbiv
-10 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.84 kW
5.42 kW
COP Tj = -7°C
2.72
2.13
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.72 kW
3.46 kW
COP Tj = +2°C
4.68
3.36
Cdh Tj = +2 °C
0.960
0.970
Pdh Tj = +7°C
3.18 kW
3.00 kW
COP Tj = +7°C
6.38
4.60
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.74 kW
3.59 kW
COP Tj = 12°C
7.88
6.18
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
6.27 kW
5.42 kW
COP Tj = Tbiv
2.64
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.27 kW
4.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.64
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
1.25 kW
Annual energy consumption Qhe
2937 kWh
3718 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.48 kW
4.94 kW
El input
0.94 kW
1.69 kW
COP
4.78
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
232 %
164 %
Prated
5.71 kW
6.10 kW
SCOP
5.87
4.16
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.71 kW
6.10 kW
COP Tj = +2°C
3.29
2.29
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
3.73 kW
4.28 kW
COP Tj = +7°C
5.59
3.58
Cdh Tj = +7 °C
0.960
0.980
Pdh Tj = 12°C
3.64 kW
3.51 kW
COP Tj = 12°C
7.36
5.59
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
5.71 kW
6.10 kW
COP Tj = Tbiv
3.29
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.71 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.29
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1299 kWh
1956 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
117 %
Prated
4.25 kW
3.92 kW
SCOP
4.11
3.00
Tbiv
-20 °C
-20 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
2.81 kW
2.28 kW
COP Tj = -7°C
3.51
2.43
Cdh Tj = -7 °C
0.970
0.970
Pdh Tj = +2°C
2.71 kW
2.53 kW
COP Tj = +2°C
5.06
3.72
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.10 kW
3.01 kW
COP Tj = +7°C
6.39
4.89
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.69 kW
3.58 kW
COP Tj = 12°C
7.84
6.44
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.03 kW
3.71 kW
COP Tj = Tbiv
2.20
1.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.03 kW
3.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.25 kW
3.92 kW
Annual energy consumption Qhe
2549 kWh
3219 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
131 %
Prated
5.75 kW
4.49 kW
SCOP
4.76
3.35
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
3.89 kW
COP Tj = -7°C
3.10
2.19
Cdh Tj = -7 °C
0.980
0.980
Pdh Tj = +2°C
3.01 kW
2.57 kW
COP Tj = +2°C
4.73
3.25
Cdh Tj = +2 °C
0.960
0.960
Pdh Tj = +7°C
3.09 kW
2.95 kW
COP Tj = +7°C
6.17
4.48
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.66 kW
3.56 kW
COP Tj = 12°C
7.60
6.06
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.37 kW
4.84 kW
COP Tj = Tbiv
2.78
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.37 kW
4.84 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2494 kWh
2766 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.48 kW
4.94 kW
El input
0.94 kW
1.69 kW
COP
4.78
2.93
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
226 %
161 %
Prated
5.71 kW
6.10 kW
SCOP
5.71
4.09
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.71 kW
6.10 kW
COP Tj = +2°C
3.29
2.29
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
3.73 kW
4.28 kW
COP Tj = +7°C
5.59
3.58
Cdh Tj = +7 °C
0.960
0.980
Pdh Tj = 12°C
3.64 kW
3.51 kW
COP Tj = 12°C
7.36
5.59
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
5.71 kW
6.10 kW
COP Tj = Tbiv
3.29
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.71 kW
6.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.29
2.29
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1335 kWh
1993 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
116 %
Prated
4.25 kW
3.92 kW
SCOP
4.08
2.98
Tbiv
-20 °C
-20 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
2.81 kW
2.28 kW
COP Tj = -7°C
3.51
2.43
Cdh Tj = -7 °C
0.970
0.970
Pdh Tj = +2°C
2.71 kW
2.53 kW
COP Tj = +2°C
5.06
3.72
Cdh Tj = +2 °C
0.950
0.960
Pdh Tj = +7°C
3.10 kW
3.01 kW
COP Tj = +7°C
6.39
4.89
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.69 kW
3.58 kW
COP Tj = 12°C
7.84
6.44
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
4.03 kW
3.71 kW
COP Tj = Tbiv
2.20
1.59
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.03 kW
3.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.20
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.25 kW
3.92 kW
Annual energy consumption Qhe
2567 kWh
3237 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
130 %
Prated
5.75 kW
4.49 kW
SCOP
4.71
3.32
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.19 kW
3.89 kW
COP Tj = -7°C
3.10
2.19
Cdh Tj = -7 °C
0.980
0.980
Pdh Tj = +2°C
3.01 kW
2.57 kW
COP Tj = +2°C
4.73
3.25
Cdh Tj = +2 °C
0.960
0.960
Pdh Tj = +7°C
3.09 kW
2.95 kW
COP Tj = +7°C
6.17
4.48
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
3.66 kW
3.56 kW
COP Tj = 12°C
7.60
6.06
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
5.37 kW
4.84 kW
COP Tj = Tbiv
2.78
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.37 kW
4.84 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
8 W
8 W
PTO
29 W
29 W
PSB
29 W
29 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2524 kWh
2796 kWh