2,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.00 kW
14.50 kW
El input
3.11 kW
5.37 kW
COP
4.50
2.70
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
134 %
Prated
11.50 kW
11.50 kW
SCOP
4.58
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.44 kW
10.50 kW
COP Tj = -7°C
2.90
2.06
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
6.69 kW
6.32 kW
COP Tj = +2°C
4.29
3.18
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
4.23 kW
4.11 kW
COP Tj = +7°C
6.37
4.83
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
4.64 kW
4.63 kW
COP Tj = 12°C
8.82
7.42
Cdh Tj = +12 °C
0.940
0.950
Pdh Tj = Tbiv
10.44 kW
10.50 kW
COP Tj = Tbiv
2.90
2.06
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.70 kW
9.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
28 W
28 W
PTO
31 W
31 W
PSB
31 W
31 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.80 kW
2.12 kW
Annual energy consumption Qhe
5182 kWh
6950 kWh