Certificate holders

Subtype

DC Inverter Heat Pump- R290- FP040

Certificate Holder
Beijing Ousheng Times New Energy Technology Co., Ltd.
No.536, Huaisha Road BoHai Town, HuaiRou District
101405 Beijing
China
Registration number
041-K080-02
Certification Body
BRE Global Limited
Subtype title
DC Inverter Heat Pump- R290- FP040
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,950 kg

Certification Date
18.12.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

FP040-DKZLRS-E/S
Configure model
Model name
FP040-DKZLRS-E/S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.04 kW

6.90 kW

El input

1.43 kW

2.20 kW

COP

4.92

3.14

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

181 %

137 %

Prated

7.89 kW

8.70 kW

SCOP

4.60

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.98 kW

7.70 kW

COP Tj = -7°C

3.14

2.38

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.26 kW

4.70 kW

COP Tj = +2°C

4.53

3.38

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.52 kW

4.41 kW

COP Tj = +7°C

6.05

4.70

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.25 kW

5.08 kW

COP Tj = 12°C

8.44

6.52

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.98 kW

7.70 kW

COP Tj = Tbiv

3.14

2.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.89 kW

7.47 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

59 °C

59 °C

Poff

5 W

5 W

PTO

23 W

23 W

PSB

5 W

5 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.23 kW

Annual energy consumption Qhe

3546 kWh

5139 kWh