Certificate holders

Subtype

EDM9016S

Certificate Holder
Foshan City Shunde Yuelly Energy-Saving Equipment Co., Ltd
C Zone No. 3 Zhanye Rd Honggang Industry Daliang Shunde Foshan City
Guangdong
China
Registration number
041-K079-04
Certification Body
BRE Global Limited
Subtype title
EDM9016S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,500 kg

Certification Date
05.12.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

EDM9016S
Configure model
Model name
EDM9016S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.33 kW

5.16 kW

COP

4.80

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

144 %

Prated

14.63 kW

14.60 kW

SCOP

4.88

3.68

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.94 kW

12.94 kW

COP Tj = -7°C

3.18

2.39

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.94 kW

7.94 kW

COP Tj = +2°C

4.54

3.40

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.89 kW

6.63 kW

COP Tj = +7°C

6.89

5.31

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.69 kW

6.28 kW

COP Tj = 12°C

8.98

7.16

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

12.94 kW

12.94 kW

COP Tj = Tbiv

3.18

2.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.55 kW

14.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

14 W

14 W

PTO

14 W

14 W

PSB

14 W

14 W

PCK

43 W

43 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.08 kW

0.00 kW

Annual energy consumption Qhe

6206 kWh

8213 kWh