1,050 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.00 kW
10.00 kW
El input
2.08 kW
3.33 kW
COP
4.80
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
9.28 kW
9.09 kW
SCOP
4.60
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.21 kW
8.04 kW
COP Tj = -7°C
3.06
2.41
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
4.97 kW
5.07 kW
COP Tj = +2°C
4.69
3.21
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.21 kW
3.86 kW
COP Tj = +7°C
5.59
4.01
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.79 kW
4.75 kW
COP Tj = 12°C
8.07
5.53
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.21 kW
8.04 kW
COP Tj = Tbiv
3.06
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.67 kW
8.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
60 °C
60 °C
Poff
10 W
10 W
PTO
10 W
10 W
PSB
10 W
10 W
PCK
40 W
40 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.61 kW
0.70 kW
Annual energy consumption Qhe
4174 kWh
5719 kWh