Certificate holders

Subtype

EDM9008

Certificate Holder
Foshan City Shunde Yuelly Energy-Saving Equipment Co., Ltd
C Zone No. 3 Zhanye Rd Honggang Industry Daliang Shunde Foshan City
Guangdong
China
Registration number
041-K079-01
Certification Body
BRE Global Limited
Subtype title
EDM9008
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,850 kg

Certification Date
05.12.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

EDM9008
Configure model
Model name
EDM9008
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.20 kW

8.00 kW

El input

1.67 kW

2.58 kW

COP

4.90

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

140 %

Prated

7.31 kW

7.35 kW

SCOP

4.70

3.58

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.47 kW

6.50 kW

COP Tj = -7°C

3.19

2.34

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.01 kW

3.94 kW

COP Tj = +2°C

4.81

3.63

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.13 kW

3.80 kW

COP Tj = +7°C

5.76

4.39

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.49 kW

3.40 kW

COP Tj = 12°C

6.85

6.77

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.47 kW

6.50 kW

COP Tj = Tbiv

3.19

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.29 kW

7.35 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.01

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

41 W

41 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.02 kW

0.00 kW

Annual energy consumption Qhe

3215 kWh

4241 kWh