Certificate holders

Subtype

ThermaX R290 9KW

Certificate Holder
GD Shenling Thermal Tech Co., Ltd
No.29 Shunye East Rd.
528325 Foshan
China
Registration number
011-1W0746
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ThermaX R290 9KW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,920 kg

Certification Date
29.11.2023
Testing basis
European KEYMARK Scheme for Heat Pumps Version 12 (2023-03)
Generate PDF Export model CSV
  • Number of models 1

Models

HPM-V90W/R3
Configure model
Model name
HPM-V90W/R3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.86 kW

2.86 kW

COP

4.85

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

150 %

Prated

9.00 kW

9.00 kW

SCOP

5.15

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.03 kW

8.03 kW

COP Tj = -7°C

2.97

2.19

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

4.84 kW

4.82 kW

COP Tj = +2°C

4.85

3.73

Cdh Tj = +2 °C

0.987

0.990

Pdh Tj = +7°C

3.09 kW

2.96 kW

COP Tj = +7°C

7.80

5.57

Cdh Tj = +7 °C

0.967

0.976

Pdh Tj = 12°C

1.75 kW

2.10 kW

COP Tj = 12°C

8.84

7.99

Cdh Tj = +12 °C

0.934

0.951

Pdh Tj = Tbiv

8.03 kW

8.03 kW

COP Tj = Tbiv

2.97

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

7.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

13 W

13 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.30 kW

Annual energy consumption Qhe

3612 kWh

4749 kWh