0,920 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
1.86 kW
2.86 kW
COP
4.85
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
150 %
Prated
9.00 kW
9.00 kW
SCOP
5.15
3.82
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.03 kW
8.03 kW
COP Tj = -7°C
2.97
2.19
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
4.84 kW
4.82 kW
COP Tj = +2°C
4.85
3.73
Cdh Tj = +2 °C
0.987
0.990
Pdh Tj = +7°C
3.09 kW
2.96 kW
COP Tj = +7°C
7.80
5.57
Cdh Tj = +7 °C
0.967
0.976
Pdh Tj = 12°C
1.75 kW
2.10 kW
COP Tj = 12°C
8.84
7.99
Cdh Tj = +12 °C
0.934
0.951
Pdh Tj = Tbiv
8.03 kW
8.03 kW
COP Tj = Tbiv
2.97
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
7.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.30 kW
Annual energy consumption Qhe
3612 kWh
4749 kWh