Certificate holders

Subtype

THERMOR Aérolia Compact Duo 4

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-C700235 / Issue 1
Certification Body
RISE CERT
Subtype title
THERMOR Aérolia Compact Duo 4
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,970 kg

Certification Date
11.12.2023
Testing basis
EN 14511:2022, EN 16147:2017, EN 14825:2022, EN 12102:2022
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

THERMOR Aérolia Compact Duo 4
Configure model
Model name
THERMOR Aérolia Compact Duo 4
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.50 kW

El input

0.95 kW

1.66 kW

COP

4.83

2.72

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

128 %

Prated

5.40 kW

4.80 kW

SCOP

4.61

3.29

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.80 kW

4.30 kW

COP Tj = -7°C

3.00

2.03

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.90 kW

2.60 kW

COP Tj = +2°C

4.45

3.14

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

1.90 kW

2.20 kW

COP Tj = +7°C

6.21

4.55

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.40 kW

2.30 kW

COP Tj = 12°C

7.99

6.29

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

4.80 kW

4.30 kW

COP Tj = Tbiv

3.00

2.03

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.30 kW

3.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.75

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

4 W

4 W

PTO

12 W

13 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.10 kW

0.90 kW

Annual energy consumption Qhe

2418 kWh

3018 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

132 %

COP

3.30

Heating up time

1:30 h:min

Standby power input

30.0 W

Reference hot water temperature

54.0 °C

Mixed water at 40°C

216 l